Installation Instructions – LSRUD4B/ LSSQUD4B Commercial LED Rough-In
Green
Ground
Wire
Figure 7.
5.
Properly align the connector as shown in (Figure 6).
Plug in the luminaire quick disconnect on the module.
6.
Ensure the connector is properly engaged.
7 .
Find the green ground wire inside cylinder and attach it
to the heatsink screw boss, using the lockwasher and
screw provided (Figure 7).
8.
Install the LED Engine and trim assembly by inserting
the torsion springs into the spring receivers located
inside the housing (Figure 8).
Cleaning
To Clean Trims:
1.
Press in on white plastic latch to remove upper
reflector and clean lens (Figure 10 & 11).
2.
Gently wipe with soft, clean, dry lint-free cloth to
remove dust.
3.
Wipe with mild detergent solution on a soft, clean
cloth to remove fingerprints and stains.
4.
Rinse with clean water and dry with soft, clean, dry
lint-free cloth.
Screw
Lockwasher
Heatsink
Screw Boss
Installation Instructions – LSRUD4B/ LSSQUD4B Commercial LED Rough-In
IB520124ML
Electrical Connection
Make certain no bare wires are exposed outside of wire nut
connectors.
1.
Provide electrical service according to the "National
Electrical Code" or your local electrical code to the
cylinder housing assembly. Supply wire insulation must
be rated for at least 90°C.
2.
Connect supply lead wires to cylinder housing lead
wires (line, neutral and ground) in the fixture using the
provided lever nut connectors. Be careful not to leave
any bare conductors outside of the connectors.
3.
Lift the orange tab on the lever nut to disengage the
wire and close to secure the wire in place (Figure 12).
4.
Connect white to white, black to black, and green (from
electrical service) on the supply side to the green wire
in the cylinder housing assembly. For dimmer wiring,
see electrical Wiring Diagram section.
Figure 8.
BLACK
WHITE
GREEN/BARE COPPER
Figure 9.
www.cooperlighting.com
CAUTION
LINE
NEUTRAL
GROUND