16
English
EN
IP CLEANING S.p.A.
Sede Legale – Registered O ce / Sede Amministrativa – Administration
V.le Treviso, 63 – Fraz. Summaga 30026 Portogruaro (VE) ITALY
We declare under our own sole responsibility that the product to which this declaration refers conforms to the following EU
Directives:
2006/42/EC – 2004/108/EC – 2000/14/EC
Harmonised standards applied:
EN 12100-1; EN 12100-2; EN 60335-1; EN 60335-2-79; EN55014-1; EN55014-2; EN61000-3-2; EN61000-3-3;
EN 61000-3-11-EN 60704-1
Product:
COLD WATER POWER-JET CLEANER
Model:
PW-C23P
Mod. I 1508AO-M / I 1610AO-M
G155-CP- I 1508AO-M / G165-CP - I 1610AO-M
Person authorised to create the Technical File.
IP CLEANING S.p.A. – U cio tecnico / Technical Dep.
V.le Treviso, 63 – 30026 Portogruaro VE Italy
The duration of the warranty is in accordance with the relevant
legislation in the country where the product is sold (unless
otherwise stated by the producer).
The warranty covers materials, construction and conformity
defects during the warranty period, during which time the
manufacturer will replace defective parts and repair or replace
the product if excessively worn in normal use.
The warranty does not cover components subject to normal
wear (valves, pistons, water gasket, oil gasket, springs, O-rings,
accessories such as hoses, guns, brushes, wheels, etc.).
The warranty does not cover defects caused by or resulting
from:
PW-C23P_cAVTB_testOTT_cod. 92067FT-PLDC94338.indb 16
Technical Data
Technical Data
Output
Maximum output
Pressure
Maximum pressure
Power
T° input
Maximum input pressure
Repulsive force of the gun to the maximum pressure
Motor insulation
Motor protection
Voltage
Sound level K = 3 db(A) :
L
(EN 60704-1)
PA
L
(EN 60704-1)
WA
Unit vibrations K = 1.5M/s
2
:
Weight
Subject to technical modi cations!
EC Declaration of conformity
WARRANTY
Unit
PW-C23P
PW-C23P
G155-CP
G165-CP
Mod. I 1508AO-M
Mod. I 1610AO-M
l/min
7.5
9
l/min
8.3
10
MPa
14
15
MPa
15
16
kW
2.5
3
°C
50
50
MPa
1
1
N
20.5
24
-
Class F
Class F
-
IPX5
IPX5
V/Hz
230/50
230/50
db (A)
84.5
84.5
db (A)
92
92
m/s
2
1.75
1.75
kg
23.5
24
dott. Giovanni Cianci
Summaga di Portogruaro, 01/06/2012
- incorrect use, abuse or neglect,
- trade, professional or hire use,
- failure to service and maintain the unit as speci ed in the
user's manual,
- unauthorised repairs,
- use of non-original accessories/spare parts,
- damage incurred during shipping or due to foreign objects or
substances and accidental damage,
- warehousing and stock keeping problems.
To register the warranty, the customer must provide proof of
purchase.
For ser vice, contac t the dealership where the
machine was purchased
16/08/12 16.42

Publicité

loading