INSTALLATION INSTRUCTIONS
For models sold in the United States only: DRCA240BSS. This model does not include a pre-installed
power cord. Use the following instructions for wiring before using the range. The power cord is not
provided. Follow all local and national wiring standards and codes.
4-WIRE POWER CORD INSTALLATION
1. Remove the terminal block access plate on the back of the appliance.
2. Loosen the screws securing the strain relief bracket.
3. Insert 4 power wires (L1, L2, N, Grounding) passing through the bracket. The neutral wire of the power
cord must be connected to the center of the terminal block. The ground wire of the power cord must be
attached to the frame using the green coloured grounding screw. The power leads must be connected to
L1 and L2.
4. Loosen the 3 power leads terminal (L1, L2, N) nuts and washers on the terminal block.
5. Plug the 3 wire terminals into the terminal block as shown and then tighten the nuts.
6. Loosen the ground nut and plug the grounding wire terminal into the nut as shown and then tighten the
nut.
7. Tighten the screws of the bracket when all cords are plugged and secured.
8. Replace the terminal block access plate.
A. Terminal block
B. Power wire
C. Neutral wire
D. Bracket
E. Ground wire