Télécharger Imprimer la page

STEINEL IR 180 UP easy Information page 12

Masquer les pouces Voir aussi pour IR 180 UP easy:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
Package contents (Fig� 3�1)
– Sensor module
– Surround
– Load module
Product dimensions (Fig� 3�2)
Product components (Fig� 3�3)
A Load module
B Twilight setting
C Time setting
D Connecting terminal screw shaft
E Connecting terminal cable duct
F Surround
G Sensor module
H Switch for light function
Detection zone (Fig� 3�4)
4� Electrical connection
Wiring diagram (Fig� 4�1)
a) Two-wire connection
b) Three-wire connection
c) Interconnecting several sensors
The supply lead is a 2 or 3-core cable:
L = phase conductor (usually black or brown)
N = neutral conductor (usually blue, optional)
L' = switched phase conductor (usually black, brown or grey)
If you are in any doubt, identify the conductors using a voltage tester; then
disconnect from the power supply again. Connect phase conductor (L) and (L')
to the terminal. Neutral conductor (N) can be connected to the terminal as an
option. A protective-earth conductor is not required.
Important: mixing up the connections will cause a short circuit in the product
or your fuse box. In this case, you must identify the individual conductors once
again and reconnect them.
Several sensor switches can be connected in parallel. This does not increase
the maximum connectable load. The neutral conductor (N) must be connected
at each sensor switch.
- 22 -
5� Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting location, taking the reach and motion
detection into consideration.
Mounting procedure
• Switch OFF power supply (Fig� 4�1)
• Connect conductors to load module.
– 2-wire connection (Fig� 5�1a)
– 3-wire connection (Fig� 5�1b)
• Push load module into the flush-mounting box (Fig� 5�2)
• Screw load module into place (Fig� 5�3)
• Fit surround and sensor module on load module (Fig� 5�4)
• Switch ON power supply (Fig� 5�5)
• Settings
"6� Function"
6� Function
Factory settings:
Twilight setting: 1000 lux (daylight mode)
Time setting: 5 seconds
To make settings, you must open the sensor module.
• Press a screwdriver onto the tab and open the flap (Fig� 6�1)
Twilight setting (Fig� 6�2/B)
The sensor's response threshold can be set in increments from 2 lux to 1000 lux
or in relation to ambient light level.
Control dial set to
: daylight operation (independent of ambient light level)
Control dial set to
:
twilight operation (2 lux)
The control dial must be turned to
performing the functional test in daylight.
Time setting (Fig� 6�2/C)
The time you want the connected lamp to stay ON for can be set in increments
from 5 seconds to a maximum of 30 minutes.
Control dial set to 5 s:
shortest time (5 seconds)
Control dial set to 5 min: 5 minutes
Control dial set to 30 min: longest time (30 minutes)
when adjusting the detection zone and
- 23 -

Publicité

loading