OPERATING INSTRUCTIONS
HANGING SCALE HS-70
ITEM NO.: 1301359
INTENDED USE
The hanging scale is intended for precise weighing of items up to a total weight of 100 kg.
The scale can be mounted to a sturdy support suitable for the total weight by using a
snap hook. The item to be weighed will be attached to the S-shaped hook. The scale is
only intended for brief, direct weighing. Dynamic weighing (e.g. bulk measurement) is not
permitted and causes measuring errors. The hanging scale is operated by batteries. Power is
supplied via two lithium button cells included in the scope of delivery.
For safety and approval purposes (CE), you must not rebuild and/or modify this product. If
you use the product for purposes other than those described above, the product may be
damaged. In addition, improper use can cause hazards such as short circuiting, fire, electric
shock etc. Read the instructions carefully and keep them. Make this product available to third
parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All company
names and product names are trademarks of their respective owners. All rights reserved.
DELIVERY CONTENT
• Hanging scale
• 2 lithium button cells (type CR2032)
• Snap hook
• S hook
• Operating instructions
SAFETY INSTRUCTIONS
Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information
on proper handling in this manual, we assume no liability for any resulting
personal injury or damage to property. Such cases will invalidate the
warranty/guarantee.
a) Persons / Product
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. These may become
dangerous playing material for children.
• Protect the product from extreme temperatures, direct sunlight, strong jolts, high
humidity, moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of operation and
protect it from any accidental use. Safe operation can no longer be guaranteed if
the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a low height
can damage the product.
• Also observe the safety and operating instructions of any other devices which are
connected to the product.
• Never use the product immediately after it has been brought from a cold room into
a warm one. The condensation generated could destroy the product. Allow the
device to reach room temperature before connecting and using it. This may take
several hours.
• The accident prevention regulations of the association of commercial insurance
for electrical systems and equipment should be observed in commercial facilities!
• Make sure no persons or objects are present underneath the item to be weighed.
Falling off could cause serious injuries.
All manuals and user guides at all-guides.com
VERSION 05/15
If you are not sure about the correct connection or use, or if questions arise which are not
covered by these operating instructions, please do not hesitate to contact our technical
support or another qualified specialist.
OPERATING ELEMENTS
1 Loop for item to be weighed
2 HOLD button
3 UNIT button
4 ON/OFF/TARE button
5 Display
6 Loop for hanging
7 Rear battery compartment
8 Snap hook
9 S hook for item to be weighed
OPERATION
a) Inserting/replacing batteries
• The hanging scale is operated by batteries. Insert new batteries when using the scale for
the first time or when "Lo" appears in the display.
• Remove the cover from the rear battery compartment for inserting and replacing batteries.
Unlock the cover at the plastic clip and then lift up the cover.
• In order to replace exhausted batteries, press the plastic clip
outwards until the button cell is unlatched. Pull the battery from
the holder.
• Insert two new lithium button cells of type CR2032 into the
compartment, observing correct polarity. The positive terminal
of both cells must be facing outwards. Push the button cells
at an angle under the metal clip and then carefully push the
battery into the holder until the plastic clip locks the battery.
Observe the polarity markings inside the battery compartment.
• Close the battery compartment properly.
b) Measurement operation
Preparation
• Search an adequately sturdy hanging device for the scale. Such device must be able to
withstand at least the total weight of the item to be weighed.
• Mount the scale to the hanging device using the snap hook (8). Make sure the snap hook is
securely closed and the scale is positioned vertically.
• Attach the S hook (9) to the loop for the item to be weighed (1).
• Press the ON/OFF button (4) to turn on the hanging scale. The scale will be ready for use
after a brief test phase. Avoid any kind of vibration or impact on the measuring loops during
this test phase.
• Once the test phase has been completed successfully, a circular icon indicating stable
measuring conditions and the reading "0.0" will appear in the left bottom corner. If not, turn
the scale off and on again. Make sure the scale is hanging vertically and does not shake or
swing.
• Press and hold the ON/OFF button for approx. 3 seconds to turn off the scale.
b) Batteries
• Correct polarity must be observed while inserting the batteries.
• Batteries should be removed from the device if it is not used for a long period of
time to avoid damage through leaking. Leaking or damaged batteries might cause
acid burns when in contact with skin, therefore use suitable protective gloves to
handle corrupted batteries.
• Batteries must be kept out of reach of children. Do not leave the battery lying
around, as there is risk, that children or pets swallow it.
• All the batteries should be replaced at the same time. Mixing old and new
batteries in the device can lead to battery leakage and device damage.
• Batteries must not be dismantled, short-circuited or thrown into fire. Never
recharge non-rechargeable batteries. There is a risk of explosion.
c) Miscellaneous
• Consult an expert when in doubt about operation, safety or connection of the
device.
• Maintenance, modifications and repairs are to be performed exclusively by an
expert or at a qualified shop.
The maximum weighing capacity of 100 kg must not be exceeded. Avoid
temperature changes while measuring, as such could cause measuring errors.