USE
Filters cleaning indication
Switching the lighting on and off
• Briefly press the lighting button to switch the lighting on or off.
• Press the lighting button for three seconds to dim the lighting.
The hood is equipped with a function that warns the user at regular
intervals when the filters are saturated.
Grease filter cleaning indicator
After 100 hours of use of the cooker hood, a beep sounds occasionally
during use and the first indicator light is flashing; the grease filters
must be cleaned (see chapter 'Maintenance').
• To reset the cleaning indicator, you must press button '+' when the
extractor hood is switched off.
Carbon filter cleaning indicator
After 350 hours of use of the cooker hood, a beep sounds occasionally
during use and the fourth indicator light is flashing; the carbon filters
must be cleaned or replaced (see chapter 'Maintenance').
• To reset the cleaning indicator, you must press button '+' when the
extractor hood is switched off.
Activation of the carbon filter cleaning indicator
In standard mode, the carbon filter cleaning indicator is not active.
If the cooker hood is used as a recirculation hood, the carbon filter
cleaning indicator must be activated.
1. Switch off the extractor hood and the lighting.
2. Press and hold button '+' for at least four seconds.
▷ The fourth indicator light will come on to confirm.
Switching off the carbon filter cleaning indicator
1. Switch off the extractor hood and the lighting.
2. Press and hold button '+' for at least four seconds.
▷ The first indicator light will come on to confirm.