• If the inner cable conductor diameter is
greater than 1.2 mm or in case of burr, the
device sockets may be destroyed.
If the required level ratios are observed, a maximum number of three amplifi ers can be operated in
a cascade.
Amplifi er voltage supply
Kathrein amplifi ers are equipped with an innovative powering concept. The amplifi ers can be powered in two ways:
1. Through remote feeding via the coaxial cable of the "H low" connection on a terminal multi-switch
2. Through connection of the optional NCF 18 power supply unit to the "DC" socket (does not include powering of
the feed system!)
Potential equalisation
For potential equalisation use an earthing wire with a cross section of at least
4 mm. The unit is to be earthed using the earthing screw provided on the unit. Each
unit in the reception system must be earthed.
System example
(Symbolic representation)
or
UAS 584 oder
Terrestrial
Terrestrische
UAS 585
antenna
Antenne
(Symbolic representation)
(Symbolische Darstellung)
Internet: www.kathrein.de
KATHREIN-Werke KG • Anton-Kathrein-Straße 1 - 3 • P.O. Box 10 04 44 • 83004 Rosenheim • GERMANY • Telephone +49 (0)8031 184-0 • Fax +49 (0)8031 184-306
All manuals and user guides at all-guides.com
EMU 250
EMU 250
(optional)
(optional)
Max. 2 mm excess
length
Clamping torque max.
3 Nm
(danger of overwinding)
Diameter
0.6-1.2 mm
free of burrs