WARNING
understand and are following all information provided in the Important Safety Information section
of this manual. Failure to follow those instructions can cause death, serious injury or property
damage.
Prior to each gas fireplace operation, check the hose and valve for evidence of excessive abrasion or
wear though the visual check hole on the side of the base. Replace visual check cap prior to operating
fireplace.
BURNER CONNECTIONS
Make sure the Natural Gas hose and quick disconnect socket connections are securely fastened to
the burner and the gas supply. If your unit was assembled for you, visually check the connection
between the burner pipe and orifice. Make sure the burner pipe fits over the orifice.
!
WARNING
Failure to inspect this connection or follow these instructions could cause a fire or an explosion.
Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
Please refer to diagram for proper installation.
If the burner pipe does not rest flush to the orifice please
contact Elementi at 800-678-7294 for assistance.
Checking for Leaks
Make a leak check solution by mixing 1-part dishwashing soap
with 3 parts water in a spray bottle.
Make sure control knob is "OFF." Then, turn natural gas on at
its source.
Spray leak solution on valve connections paying particular
attention to the areas indicated by arrows.
If any bubbles appear turn natural gas off, reconnectand
re-test. If you continue to see bubbles after several attempts,
disconnect natural gas source and contact Elementi at
800-678-7294 for assistance.
If no bubbles appear after one-minute turn source OFF, wipe
away solution and proceed.
PRE-USE INSTRUCTIONS
Before using this outdoor fire table, make sure you have read,
Check for leaks at these locations
12 / 20