Troubleshooting
Built-in Heater Ready Light does not illuminate.
Possible Causes:
The Heater Switch is not turned ON ( I )
1
The Power Switch is not turned ON ( I )
2
Reduced Spray or No Spray.
Possible Causes:
Water Tank may be empty
1
Formula Tank may be empty
2
Tanks may not be seated completely
3
Pump may have lost prime
4
DirtLifter PowerBrushes do not turn
Possible Causes:
The Brush is off or broken
1
The unit is in the upright position
2
Circuit Breaker may have tripped
3
Carpet Protector is not spraying
Possible Causes:
Cartridge is not connected to the tool
1
Ready Tools Dial on Floor Setting
2
Solution clogging the Spray Trigger
3
WARNING:
To reduce the risk of
fire, electric shock or
injury unplug from outlet
before servicing.
Remedies:
Turn the Heater Switch ON ( I ).
1
Both switches must be ON ( I ) to
2
activate the Heater Ready Light.
Remedies:
Fill Heavy Duty Bladder with hot
1
tap water.
Fill Formula Tank with BISSELL Fiber
2
Cleansing Formula for cleaning.
Turn Power OFF (O). Remove and
3
reseat tanks.
Turn Power OFF (O) and then back
4
ON ( I ). Wait one minute, then
depress Trigger.
Remedies:
Turn the machine OFF (O) and unplug
1
from outlet. Follow instructions on
page 17.
Brushes only rotate when unit is
2
reclined using the detent pedal.
Turn the machine OFF (O) and unplug
3
from outlet. Check to see if foreign
object is caught in brush roll. Remove
object. Plug machine back in to reset
circuit breaker.
Remedies:
Follow instructions on cartridge to
1
assure proper fit.
Set Ready Tools Dial to Hose
2
Attachments Setting.
Soak Applicator Tool only in hot water.
3
Spray without the cartridge attached
to purge any residual solution left in
the tool.
19