Bare Floor Cleaning (Continued)
Slowly move the machine forward and back over
9.
bare floor surface one time while depressing
trigger. Caution: Do not overwet.
Repeat the motion without pressing the trigger
10.
using the Bare Floor tool to squeegee and
suction up the dirty water.
Allow approximately 30 minutes for floors to dry.
11.
Remove Bare Floor tool and rinse and dry to store.
12.
If any formula remains in the Formula Tank, pour
13.
it back into the Hard Floor Solutions bottle for
use the next time.
Rinse out the Formula Tank.
14.
Belt Removal and Replacement Instructions
Occasional replacement of one or both belts
may become necessary. If that is needed,
please follow the instructions below.
Turn off the machine, and unplug it from the outlet.
1.
Remove both the Water Tank and the Formula
2.
Tank. Set aside.
Unscrew the Front Nozzle and remove it. Set aside.
3.
Turn the machine on its side.
4.
IMPORTANT: cord side down.
Remove the Clear End Cap by unscrewing the 2
5.
Black Screws. Take care not to drop the screws
into the unit.
Remove 1 Silver Screw.
6.
Remove Pivot Arm by gently lifting up.
7.
Remove Small Brush Belt.
8.
Replace Small Brush Belt, and Reverse Steps
9.
Above.
WARNING:
To reduce the risk of fire,
electric shock or injury,
unplug from the outlet
before servicing.
1
2
3
3a
4
5
6
7
8
9
�
�
17