PARAMETER
Pr01
Ignition cycle maximum time
Flame stabilisation time during the "FIRE ON" phase
Pr02
Pr03
Time interval between two brazier cleaning operations
ON time of the screw feed motor reducer in the "LOAD PELL" phase
Pr04
ON time of the screw feed motor reducer in the "FIRE ON" phase
Pr05
ON time of the screw feed motor reducer in the "Po1" work phase
Pr06
ON time of the screw feed motor reducer in the "Po2" work phase
Pr07
ON time of the screw feed motor reducer in the "Po3" work phase
Pr08
ON time of the screw feed motor reducer in the "Po4" work phase
Pr09
ON time of the screw feed motor reducer in the "Po5" work phase
Pr10
Pr11
Temperature below which the pellet side switches on (on Pell On)
Pr12
Temperature differential for switch-off
Pr13
Flue gas minimum temperature in order to consider the thermo stove on
Flue gas maximum temperature accepted; if this occurs, the power is reduced to minimum and the flue gas intake device speed is taken to
Pr14
the maximum value
Pr15
Minimum temperature to be reached for pump switch-on
Flue gas intake speed in the "LOAD PELL" phase
Pr16
Flue gas intake speed in the "FIRE ON" phase
Pr17
Flue gas intake speed in the "Po1" work phase
Pr18
Flue gas intake speed in the "Po2" work phase
Pr19
Flue gas intake speed in the "Po3" work phase
Pr20
Flue gas intake speed in the "Po4" work phase
Pr21
Flue gas intake speed in the "Po5" work phase
Pr22
Time after which the thermo stove switches off if the boiler temperature is greater than that set in the "Set H2O"
Pr23
Pr24
Brazier cleaning duration
Pr25
Differential on the H20 Set (boiler thermostat) for 3-way valve switch-over
Pr26
Differential on the Set Sani to switch-over the 3-way valve
Pr27
Switch-over delay
Pr28
Flue gas temperature threshold for thermo stove switch-off
CIRCUIT BOARD PARAMETERS PROGRAMMED IN THE FACTORY
MAIN WORDING ON THE DISPLAY
DISPLAY
Fun
IGNITION PHASE OF THE FLUE GAS INTAKE DEVICE
ASP
(duration about 10 seconds)
LoAd
PELLET LOADING AND FLAME IGNITION PHASE
PELL
(duration about 8-10 min)
FirE
FLAME STABILISATION PHASE
ON
(duration about 8-10 minutes)
Po 1...Po 5= work power from 1 to 5.
Po1 , Po2 ,
61 °C
Boiler water temperature in degrees centigrade
CooL
BRAZIER CLEANING CYCLE
FirE
ECONOMY FUNCTIONING
Eco
Temperature in boiler the same or greater than that set via
H2o
"SeT H2o"
FIRE OFF
This occurs with boiler temperature 10 °C over the
temperature set with SeT H2O or after 2 hours functioning
StoP
in economy. When the temperature in the boiler lowers by
FirE
at least 10 °C the thermo stove starts automatically. It is
also displayed when, the wood side switches off with the
"Pell on" function active.
Read the instruction manual for all of the other wording shown on the display.
All manuals and user guides at all-guides.com
General parameters
DESCRIPTION
DESCRIPTION
DISPLAY
Eco
ROOM THERMOSTAT CONTACT OPEN
toFF
FLUE GAS TEMPERATURE TOO HIGH
Eco
The thermo stove automatically slows the power until the
flue gas temperature is lowered. Clean the internal "flue
Fumi
gas pass" as soon as possible.
STAND-BY
OFF
This occurs when attempts are made to re-ignite the
At te
thermo stove before the flue gas intake device has finished
the switch-off cycle.
NO FIRE
NO
This occurs when for some anomaly the thermo stove
FirE
switches off without displaying alarms. It can also occur
in the switch-on phase if the pellet side does not ignite.
NO WATER
It occurs when the water inside the thermo stove is not at
no
correct level
H2o
Remove the upper majolica and the lid in order to verify
that the water inside the boiler body is at a level that it
covers the exchangers completely.
25
VALUE
18'
5'
90'
2,8"
2,2"
2,2"
3,3"
4,5"
5,8"
6,8"
60
10
56
260
55
30
26
8
12
18
23
27
120'
50"
10
5
60"
80
DESCRIPTION