Thermo stove working mode (PELLET SIDE)
During normal thermo stove functioning, the upper display will show the power set (P1, P2, P3, P4, P5, SAni), while the lower display shows the temperature
SET. The work power can be modified by the user via buttons 5 and 6. During this phase the thermo stove works at the power set if the temperature in
the boiler is lower than the temperature SET. The thermo stove starts to modulate, lowering the intake of pellets and reducing the flue gas intake speed on
reaching the temperature set by the SET temperature decreased by 5 degrees.
Example: SET temperature set at 75°C.
Work power set at 5.
On reaching 71°C in the boiler, the power is automatically taken to 4.
On reaching 72°C in the boiler, the power is automatically taken to 3.
On reaching 73°C in the boiler, the power is automatically taken to 2.
On reaching 74°C in the boiler, the power is automatically taken to 1.
On reaching 75°C in the boiler, the thermo stove goes into "Eco H2o" (functioning economy).
The thermo stove switches off automatically if it remains infunctioning economy for more than 2 hours (Pr23) or if it exceeds the temperature set on "Set
H2o" by 10°C (Pr12).
Any room thermostat connected to the thermo stove will act on the functioning of the same, sending it into functioning economy mode (the display shows
"Eco toFF"). It is however fundamental, that the room thermostat does not close any system zone valves, because when excess heat occurs due to the
inertia of the thermo stove, this will be disposed of by starting the pump until the boiler temperature goes back to normal temperature. In the case of a black
out, if the interruption of the current is less than 20", on return of the electric energy, the thermo stove re-starts at the working power that it had previously,
otherwise the display shows the "StoP FirE" anomaly status. The intake will be increased to maximum in order to expel residual flue gas. When the stove
has cooled, the ignition phase is re-started.
If key 1 is pressed during functioning, the upper display shows the temperature of the pellet side outlet flue gas. By pressing key 2 it is possible to display the
temperature of the fumes of the wood side. The brazier cleaning cycle is performed at pre-established intervals of time (indicated in the display with "CooL
FirE") for a duration which is also established.
Switch-off of the thermo stove (PELLET SIDE)
Pressing button 4 (ON/OFF) switches the stove off. The upper display will show "OFF". The flow of pellets is interrupted, switching the motor reducer off. The
flue gas intake device speed is increased to maximum and is switched off after about 10 minutes.
Modifying set temperature
The value of the maximum temperature in the boiler can be varied at any time by the user. To modify it enter in SET temperature by pressing button 3 (SET
and then with buttons 1 and 2 select the desired value (do this when the stove works at a power from 1 to 5).
Producing domestic hot water (prepared models only)
The domestic hot water is produced instantly via a double heat exchanger immersed in the water inside the thermo stove.
Therefore, to have domestic hot water it is necessary that the thermo stove is in temperature (at least 60°C).
If a large amount of domestic hot water is required, the thermo stove must be set in "SAni"
The domestic hot water power function (Sani) is that of delaying start-up of the heating pump at higher temperatures in a way to give-up all of the heat
developed under that temperature to the domestic hot water.
Working in "Sani" there is the possibility of setting the start-up temperature of the pump during this power by pressing the SET key and varying the
temperature of the "Set Sani" using keys 1 or 2 (it is recommended to keep this temperature on 70–75 °C).
When domestic hot water is no longer required, it is recommended to re-set the thermo stove with work power from Po1 to Po5.
If the water is particularly hard, it is indispensable to install a lime scale device at the inlet to the heat exchanger, which must be selected on the
basis of the features of the water.
Chrono-thermostat
The chrono-thermostat function allows to program automatic switch-on/off of the thermo stove throughout the week (pellet side).
The chrono-thermostat has priority over all functioning of the thermo stove.
Therefore:
If PELL OFF is set, the pellet side switches on and switches off at the times set with the wood side on or off
If PELL ON is set, the pellet side switches on and switches off at the times set with the wood side on or off
PARAMETER
UT01
Sets the current day and method of use
UT02
Sets the current time
UT03
Sets minutes
UT04
Sets technical parameters (RESERVED)
UT05
Sets PROGRAM 1 switch-on time
UT06
Sets PROGRAM 1 switch-off time
UT07
Choice of days with stove ignition
UT08
Sets PROGRAM 2 switch-on time
UT09
Sets PROGRAM 2 switch-off time
UT10
Choice of days with stove ignition
UT11
Sets PROGRAM 3 switch-on time
UT12
Sets PROGRAM 3 switch-off time
UT13
Choice of days with stove ignition
UT14
Sets PROGRAM 4 switch-on time
UT15
Sets PROGRAM 4 switch-off time
UT16
Choice of days with stove ignition
Press button 3 twice to enter programming. Press button 3 again to scroll all of the programming parameters explained below. Pressing key 4 allows to exit
programming ay any time.
All manuals and user guides at all-guides.com
DESCRIPTION
15
VALUE THAT CAN BE SET
OFF, Mon, Mar, Wed, ..., Sun
From 00 to 23
From 00 to 59
From 00 to P5
From 00:00 to 23:50 in 10' steps
From 00:00 to 23:50 in 10' steps
Between on/off from Mon to Sun
From 00:00 to 23:50 in 10' steps
From 00:00 to 23:50 in 10' steps
Between on/off from Mon to Sun
From 00:00 to 23:50 in 10' steps
From 00:00 to 23:50 in 10' steps
Between on/off from Mon to Sun
From 00:00 to 23:50 in 10' steps
From 00:00 to 23:50 in 10' steps
Between on/off from Mon to Sun