Increase
temperature
Decrease
temperature
State/Time/Temperature Display
Size value
The buttons
N° 1 Increase temperature
In <SET TEMPERATURE> mode, it is allowed to increase the boiler water maximum temperature thermostat value.
N° 2 Decrease temperature
In <SET TEMPERATURE> mode, it is allowed to decrease the boiler water maximum temperature thermostat value.
N° 3 Set/Menu
The button allows to access the set temperature and the user and technician parameters menu. Inside the menu it is possible to scroll the list of sizes by
pressing the button repeatedly. The upper display will show the name of the parameter and the lower display the value it assumes. Pressing the button
once enters the temperature set menu, pressing again rapidly, goes to the user/technician menu.
N° 4 On/Off and Release
The button, pressed for two consecutive seconds, allows manual switch-on/off of the thermo stove depending whether it is respectively off or on. When
alarms have occurred that have led the thermo stove itself to Block conditions, the button allows release and the successive passage to the off status.
During programming of the user/technician parameters, it allows to exit the menu at any time.
N° 5 Increase power
When in work mode, the button allows to increase the power value of the thermo stove from a minimum of 1 to a maximum of 5.
N° 6 Decrease power
When in work mode, the button allows to decrease the power value of the thermo stove from a maximum of 5 to a minimum of 1; this value is given on
the upper display. By pressing the button for 2" with the stove off, the flue gas intake device switches on for 10 minutes, thus making cleaning easier.
The LEDs
The control unit has the following LEDs:
Chrono active LED
The LED is on when the UT1 parameter inside the menu is different to OFF, thus setting the weekly and daily programming;
Room Thermostat LED
The LED is on when the relative inlet is open;
Resistance ON LED
The LED is on for the entire interval of time during which the ignition resistance is on. This occurs during the start phase when the fire must be ignited;
Flue gas intake device ON
The LED is on for the entire interval of time during which the flue gas suction device is enabled;
Pump ON LED
The LED is on for the entire interval of time during which the water pump is on;
Screw feed ON LED
The LED is on for the entire interval of time during which the screw feed is enabled and the motor reducer that makes the screw feed turn is on. This
occurs in the START and WORK phase;
Remote control reception LED
The LED flashes when the console receives a temperature or power modification command from the infra-red remote control;
Temperature reached OK LED
The LED is on for the entire interval of time during which the thermo stove reaches the temperature set on the water thermometer via the SET button;
Temperature set LED
The LED flashes when inside the SET temperature.
All manuals and user guides at all-guides.com
Resistance ON
LED
Thermostat LED
Open environment
Chrono ON
LED
°C
1
Set
2
3
Set/Menu
Pump ON
LED
Flue gas
intake device ON LED
State/power display
Parameter name
Data receipt
remote control LED
Screw feed
ON LED
OK
4
SET
Set
temperature LED
Boiler water temperature
reached LED
12
Increase
power
5
6
S.R.L.
On/Off
Decrease
power

Publicité