No.
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
14
Function
Parameter LED indicator
when a parameter is selected, the LED indicator under the relevant symbol lights
up.
Arc length correction
Droplet detachment correction/arc force dynamic correction/arc
force dynamic
Welding voltage
Welding speed
o
Job N
Digital display (right)
Wire-feed unit drive current-input LED indicator
lights up when the wire-feed unit drive current-input indicator parameter is select-
ed
Parameter selection button
for selecting the following parameters:
Arc length correction
Droplet detachment correction/arc force dynamic correction/arc
force dynamic
Welding voltage
Welding speed
(only on power sources with Comfort control panel)
o
Job N
Wire-feed unit drive current-input indicator
indicates that the wire-feed unit drive is consuming current
More detailed information on the parameters can be found in the "Explanation of
parameters" section below.
Welding process LED indicators
when a welding process is selected, the LED indicator under the relevant symbol
lights up.
MIG/MAG pulse synergic welding
MIG/MAG standard synergic welding
MIG/MAG standard manual welding
Job Mode
Welding process button
for selecting the welding process
MIG/MAG pulse synergic welding
MIG/MAG standard synergic welding
MIG/MAG standard manual welding
Job Mode
Store button
for accessing the Setup menu or for saving parameter settings in Job Mode
Adjusting dial
for altering parameters. If the indicator on the adjusting dial is lit up, then the se-
lected parameter is one that can be altered.