• Remove the transparent label remaining in the upper part of the adhesive sheet
and stick it over the previous one affixed to the loading point.
Avoid the emission of the fluorinated gas contained here.
Make sure that the fluorinated gas is never released into the atmosphere during
installation, assistance and disposal.
• Whenever a fluorinated gas leak is detected, the leak must be found and repaired
as quickly as possible.
ONLY qualified personnel must provide assistance on this product.
Any use of fluorinated gas in this appliance, e.g. during manual movement of the
product or re-loading the gas, must be compliant with the regulations regarding
determined fluorinated greenhouse gases and any applicable local laws.
2.6.7 - Connection of the condensate drain line
Connect a drain pipe, of appropriate length, to the indoor unit condensate drain pipe, and block it with a strap.
Make it run inside the duct parallel to the system pipes, fastening it to the same using straps.
Do not tighten the straps excessively in order to prevent damage to the insulation
of the pipes and narrow the drain pipe.
Where possible, make the condensate liquid flow directly into a rainwater gutter.
If the drain pipe is fed into a sewage system, it is necessary to bend the pipe in
order to create a siphon (figure 25), in order to avoid the diffusion of unpleasant
odours into the environment.
The siphon bend must never be at a level below 1500 mm from the lower wire of
the appliance (figure 25).
If draining is into a recipient (figure 26), this must never be closed so as not to
prevent counter-pressures such to compromise the operation, and the pipe itself
must never reach the level of the liquid deposited.
Check the correct run-off of the condensate liquid through the relative pipe by very
slowly pouring approx. 1/2 litre of water into the collection tray of the indoor unit
(figure 27).
EN - 22