AXIS A1601 Network Door Controller
•
When the Axis product has reached the end of its useful life, dispose of it according
to local laws and regulations. The product should not be disposed of together with
household or commercial waste. See on page 3 .
•
Do not connect the Axis product to a receptacle controlled by a switch.
•
Battery
-
The 3.0 V lithium battery used by the Axis product is a UL recognized
component. (Type: BR2032, diameter: 20 mm (0.78 in), manufacturers:
Rayovac (Spectrum), Panasonic, Renata). The following battery type is also a
UL recognized component: Type CR2032.
-
Users shall not replace the battery. If the battery needs replacing, it must
be done by a trained technician only.
-
Used batteries shall be disposed of according to local laws and regulations,
which may vary from state to state. Waste BR/CR lithium cells are neither
listed nor exempted from the USEPA hazardous waste regulations. Waste
lithium batteries can be considered reactive hazardous waste if there is a
significant amount of unreacted, or unconsumed lithium remaining. For
information about how to dispose of used lithium batteries, contact your local
authority for waste disposal.
Specifications
•
Operating Conditions
Normal use (not evaluated by UL)
1
NEMA TS-2
(Not verified in UL294)
Conditional specification, read note below.
UL 294 and UL 293
1.
To meet the NEMA TS-2 temperature range the following restrictions apply: Only DC IN as power source
(PoE is not allowed). The lock(s) must be supplied by external voltage (12 V DC or 24 V DC supplied by the
A1601 is disallowed). Only one reader connected with maximum average current of 130 mA at 12 V.
•
Wiring requirements
-
UL listed or R/C AWM wires that have a conductor gauge range of
AWG 22–14 shall be used.
-
The minimum conductor gauge for connection between the power sourcing
equipment (PSE) or power injector and the powered device (PD) is 26 AWG.
-
Minimum PoE category 5e, shielded cable, required for PoE.
-40 °C to 55 °C (-40 °F to 131 °F)
Humidity 20–85% RH (non-condensing)
-34 °C to 74 °C (-30 °F to 165 °F)
Humidity <95% in the range of 4.4 °C (+40 °F)
to 43.3 °C (110 °F)
0 °C to 74 °C (32 °F to 165 °F), maximum
humidity 85%
30