Télécharger Imprimer la page

Axis Communications A1601 Instructions D'installation page 29

Publicité

Requirements for compliance with UL 294 and UL 293
This section contains information and instructions required for UL compliance. To make sure the
installation is UL compliant, follow the instructions below in addition to the general information
and instructions provided throughout this document. In cases where pieces of information
contradict each other, the requirements for UL compliance always replace general information
and instructions.
Performance Levels for Access Control
This section contains performance level information required for UL 294 and UL 293 compliance.
Feature
Destructive Attack Test
Security
Endurance
Standby Power
The control panel must be programmed to provide a local audible output to annunciate
AC power loss, door held open, and door forced open for UL 293 compliance.
Supported readers
For UL 294, compatibility with the following readers has been verified by UL:
HID iClass RK40, AXIS A4010-E. For UL 293 applications, readers must be listed to UL
293. UL has not verified any UL 293 readers.
Safety instructions
The Axis product shall be installed and serviced by a factory trained professional.
The Axis product shall be Installed in accordance with the Secured by Design HOMES
directive for UL 293 compliance.
The Axis product shall be installed within the protected premises (secured area).
The Axis product shall be mounted indoors. Outdoor use has not been evaluated or
approved by UL.
All interconnecting devices shall be UL listed and Class 2 low-voltage power limited.
All power outputs are Class 2 outputs.
All wiring methods shall be performed in accordance with ANSI/NFPA70, local codes and
authorities having jurisdiction.
Recommend to use UL recognized grounding wire, a size of 14-16 AWG, yellow/green
color. Crimp the cable on the non-insulated wire pressure ring terminal which is being
delivered as a spare part of the product. Important to use proper crimping tool and
techniques to ensure the safety of product and user.
AXIS A1601 Network Door Controller
Level
I
I
IV
I
29

Publicité

loading