Power connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant limited
power source (LPS) with either a rated output power limited to ≤100 W or a rated output current
limited to ≤5 A.
Function
Pin
1
0 V DC (-)
2
DC input
UL: DC power to be supplied by a UL 294, UL 293 or UL 603 listed power supply, depending on
application, with appropriate ratings.
Backup battery input connector
For a backup solution using a battery with built-in charger. 12 V DC input.
UL: The connector has not been evaluated by UL.
Important
When the battery input is used, an external 3 A slow blow fuse must be connected in series.
AXIS A1601 Network Door Controller
Notes
For powering controller when not using
Power over Ethernet.
Note: This pin can only be used as
power in.
27
Specifications
0 V DC
10.5–28 V DC, max 36 W