Skilled Personnel - WIKA TR10-L Mode D'emploi

Masquer les pouces Voir aussi pour TR10-L:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2. Safety

Skilled personnel

Skilled personnel are understood to be personnel who, based on their technical training,
knowledge of measurement and control technology and on their experience and knowledge of
country-specific regulations, current standards and directives, are capable of carrying out the
GB
work described and independently recognising potential hazards.
Special operating conditions require further appropriate knowledge, e.g. of aggressive media.
2.3 Additional safety instructions for instruments with ATEX approval
WARNING!
Non-observance of these instructions and their contents may result in the loss of
explosion protection.
WARNING!
Thermometers with EEx d approval should only be opened once the power has been
disconnected fo at least 2 minutes.
WARNING!
Follow the requirements of the 94/9/EC (ATEX) directive.
Follow the respective national regulations concerning Ex-usage (e.g. EN 60 079-10
and EN 60 079-14).
2.3.1 Conditions from type examination certificate TÜV 02 ATEX 1858 X
Equipment Category classification
Marking
2 fault safety (e.g. with sensor supply circuit
"ia")
II 1/2 GD EEx d IIC T80 °C IP 65
resp. II 1/2 G EEx d IIC T6
II 1/2 GD EEx d IIC T95 °C IP 65
resp. II 1/2 G EEx d IIC T5
II 1/2 GD EEx d IIC T130 °C IP 65
resp. II 1/2 G EEx d IIC T4
II 1/2 GD EEx d IIC T195 °C IP 65
resp. II 1/2 G EEx d IIC T3
II 1/2 GD EEx d IIC T290 °C IP 65
resp. II 1/2 G EEx d IIC T2
II 1/2 GD EEx d IIC T440 °C IP 65
resp. II 1/2 G EEx d IIC T1
1 fault safety with power reduction (e.g. with
sensor supply circuit "ib")
II 1/2 GD EEx d IIC T80 °C IP 65
resp. II 1/2 G EEx d IIC T6
II 1/2 GD EEx d IIC T95 °C IP 65
resp. II 1/2 G EEx d IIC T5
II 1/2 GD EEx d IIC T130 °C IP 65
resp. II 1/2 G EEx d IIC T4
6
Temperature maximum in °C
at the thermowell/measuring insert
Power P
at the sensor: *
max
50 mW
100 mW
250 mW
63
61
56
75
73
68
103
101
96
155
153
148
231
229
224
351
349
344
50 mW
100 mW
56
46
68
58
96
86
WIKA Operating Instructions Model TR10-L/TC10-L EEx d
Neck length
Temperature
minimum
range ambient
1
M h *
2
500 mW
46
-
-20 ... 55 °C
56
-
-20 ... 70 °C
86
20 mm
-20 ... 100 °C
138
50 mm
-20 ... 100 °C
214
100 mm
-20 ... 100 °C
334
100 mm
-20 ... 100 °C
-
-20 ... 55 °C
-
-20 ... 70 °C
20 mm
-20 ... 100 °C
T a * 3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tc10-l

Table des Matières