Remove Control Knobs & Control Panel for Leak Testing
You will need: Phillips & flathead screwdrivers .
A) Locate door pin release in door assembly . Using a screwdriver, push down on door
pin release (1) until door detaches from frame assembly . Pull top of door away from
frame assembly (2) and lift door off bottom adjustable hinge pin .
B) Remove control knobs, igniter button, retention nut, and battery (3) .
C) Remove screws from wind deflector with a Phillips screwdriver (4) .
D) Tilt end of wind deflector down and slide wind deflector away to remove (5) .
E) Let igniter module dangle from wires . Do not disconnect (6) .
F) Remove screws from underside of control panel with Phillips screwdriver (7) .
G) Lift control panel up slightly, tilt up front edge and gently lift up (8) .
H) Replace control panel and wind deflector when leak check is completed .