Step 2 - Wall Profile Positioning
1.
On both wall profiles drill three 4.5mm holes through the lip. Place them 7mm
in from the edge and approximately 100mm from each end and the other
positioned in the centre.
•
Drill the holes from the back (through the face that goes to the wall) -
deburr all holes.
2.
Place both Wall Profiles 10mm in from the outside of the tray. Make sure that
both Wall Profiles are completely vertical using a spirit level and mark the wall
through the holes with a pencil.
3.
Drill the wall with a 6mm Masonry Drill Bit (not supplied) where the Wall
Profiles are to be positioned. Fit the Wall Plugs supplied (if going in to a brick
or block wall). If going into a plasterboard wall you will need to purchase
appropriate wall fixings. Wipe clear all debris from the Tray before referring to
the next stage.
4.
Take one Wall Profile and position it on the Tray, place a bead of Bathroom
Sealant (not supplied) the width of the Wall Profile between the tiled wall and
tray. Fit Screw Bases to the 40mm screws (supplied) and secure the Wall
Profile to the wall. Do not over tighten the screws into the Wall Profile as this
will misshape the Wall Profile. Ensure the Wall Profile stays completely vertical
throughout this procedure using a Spirit Level.
•
NOTE: Only one Wall Profile is fitted at this time, the other Wall Profile is
fitted later.
•
NO sealant should be present between the Wall Profiles and the tiled
walls vertically prior to screw fixing.
5.
Seal the gap between the Tray and Wall Profile with a Bathroom Sealant (not
supplied).
•
Failure to carry out Stages 4 & 5 can result in serious water damage and
is not covered by the Guarantee.
5
2
Sanindusa S.A. reserva o direito de fazer alterações técnicas sem aviso prévio.
Sanindusa S.A. reserva el derecho de hacer alteraciones técnicas sin previo aviso.
7mm
Screw Base
1
4
Step 3 - Positioning the Door & Second Wall Profile
1.
Place the remaining Wall Profile at the required end of the Door.
2.
Gently lift the Door and Wall Profile onto the tray and into the already fixed Wall Profile.
3.
Where the unfixed Wall Profile will meet the tiled wall and tray apply a generous bead of sealant.
4.
Position the Wall Profile so that it locates over the previously fitted wall plugs.
5.
Fit Screw Bases to the 40mm screws (supplied) and secure the Wall Profile to the wall. Do not over
tighten the screws into the Wall Profile as this will misshape the Wall Profile. Ensure the Wall Profile
stays completely vertical throughout this procedure using a Spirit Level.
6.
Position the Door equally between the Wall Profiles, there must be at least 6mm left for fixing.
NOTE: This part of the installation requires 2 people.
3
Sanindusa S.A. reserves the right to introduce technical improvements without previous notice.
Width of
Wall
Profile
4
Sanindusa S.A. réserve le droit de faire des altérations techniques sans information prealable.
Sanindusa S.A. si reserva il diritto di effettuarre cambiamenti tecnici sensa preaviso.
1
Drill this
face
2
10mm
2
3
Width of
the Wall
Profile
5
Screw Base
2
3
3