OPTOTRONIC
LED Power Supply
®
12)
Position
14)
A or B
Input / PRI + DALI, one cable
16)
A and B
Input / PRI + DALI, two cables
C
D
Installing and operating information:
Connect only LED load type. LED module will be
switched off when output voltage is outside the voltage
range given on the driver.
Wiring information (see fig. A):
Do not connect the outputs of two or more units. The
DALI interface provides basic insulation against mains.
The metal surface on LED driver underside of OTi DALI
40 NFC LP I is double insulated against mains and DALI
interface, also the metal surface is SELV basic insulated
against LED output. Output current adjustment = via
programming software using the DALI interface or via
Near Field Communication (NFC) in mains off mode only.
For Near Field Communication (NFC) please refer to
Tuner4TRONIC at www. inventronics- light. com Unit is
permanently damaged if mains is applied to the terminals
21/22. Lines 21/22 max. 2 m whole length excl. modules.
Emergency Lighting:
This LED power supply complies with EN 61347-2-13
Annex J and is suitable for emergency lighting fixtures
according to EN 60598-2-22 except those used in high-
risk task areas.
2
Output / SEC
Output / SEC
Cable type (tested acc. to EN 60598-1)
• NYM-J 5x1.5
• NYM-J 3x1.5
• H05VV-F 5x1.5
15)
• H05VV-F 3x1.5
• H05VV-F 2x1.5
• H05VV-F 2x1.0
• NYM-J 3x1.5
• H05VV-F 3x1.5
17)
• H05VV-F 2x1.5
• H05VV-F 2x1.0
• H05VV-F 2x1.5
• H05VV-F 2x1.0
• H03VV-F 2x0.75
• H03VV-F 2x0.5
• Style 21520
• H03VVH2-F 2x0.75
Hereby, Inventronics GmbH declares that the radio equip-
ment types OTi DALI 15 NFC LP I, OTi DALI 25 NFC LP
I and OTi DALI 40 NFC LP I are in compliance with Direc-
tive 2014/53/EU and the relevant statutory instruments.
The full text of the EU declaration of conformity or the
UK declaration of conformity is available at the following
internet address: www. inventronics- light. com
Frequency range:
13 553 – 13 567 kHz.
Technical support:
www.inventronics-light.com
1) Constant current LED Power Supply. 2) Wire Prepa-
ration. Push in. 3) t c point. 4) Made in China. 5) picture
only for reference, valid print on product. 6) Mains.
7) Input. 8) Output. 9) Year. 10) Week. 11) Safety note
for mounting with metal screw: The distance between
the metal screw and the insulated single wires must be
at least 2.5 mm. 12) Position. 13) Cable types (tested
acc. to EN 60598-1) 14) A or B. 15) one cable. 16) A
and B. 17) two cables