2.3.1. Cutting and gluing of accessories
Cut the pipe to the proper length to install the electrolysis cell. To do this, you can use the
supplied template and follow the steps below:
1) Place the template horizontally along the
pipe where you want to install the equipment.
2) Using a permanent marker, mark 4 lines on
the tube through the slots in the template.
3) Remove the template and cut the PVC pipe
at the two points marked A. Pay attention
and make sure you cut the correct points (the
two lines on the inside).
4) Apply cleaner between the ends resulting
from the cut, and the points marked as B.
Also clean the fittings to be glued. Be sure to
choose the right ones for your pipe (two sets
of sizes are provided: 50 and 63mm).
Cutting marks
5) Apply PVC glue all around the cut pipe and
the fitting to be glued, and press the fitting
into the pipe until it stops.
6) Repeat the operation with the fitting and
pipe on the opposite side.
7) Wait for the glue to harden. The waiting
time will depend on the glue used, please
refer to the product instructions carefully.