Zone parameters
•
Associated outputs. This displays and allows you to select the control outputs associated to
the thermostat.
•
Thermostat settings. This allows you to set up the thermostat as Master or Zone.
Note: It cannot be configured as Master if there is already another thermostat configured
as such.
•
Use mode. (Only available through Airzone Cloud). This allows you to configure the
thermostat for the system's different zones in Basic or Advanced mode. By default, it is set
to Advanced. The parameters that can be controlled in Basic mode are:
- On/Off.
- Set point temperature.
- Operation mode (only if this is the master thermostat).
- Fan speed.
If you need to reset the thermostat to Advanced mode, access the Advanced settings menu
and activate Advanced use mode.
•
Offset. This allows you to correct the room temperature measured in the different zones or
in all of them, due to deviations produced by sources of heat/cold nearby, with a correction
factor between - 2,5 °C / - 5 ºF and 2,5 °C / 5 ºF in steps of 0,5 °C / 1 ºF. By default, it is set to 0
°C / 32 ºF.
•
User mode set point. This option is used to configure the set point temperature of each
user mode for each zone:
o Comfort. Heating mode: 15 to 30 ºC / 59 to 86 ºF, by default 20 ºC / 68 ºF. Cooling mode:
18 to 30 ºC / 64 to 86 ºF, by default 24 ºC / 75 ºF.
o Eco. Heating mode: 15 to 30 ºC / 59 to 86 ºF, by default 19 ºC / 66 ºF. Cooling mode: 18 to
30 ºC / 64 to 86 ºF, by default 25 ºC / 77 ºF.
o Unoccupied. Heating mode: 15 to 22 ºC / 59 to 72 ºF, by default 17 ºC / 63 ºF. Cooling
mode: 24 to 30 ºC / 75 to 86 ºF, by default 27 ºC / 81 ºF.
o Vacation. Heating mode: 10 to 16 ºC / 50 to 61 ºF, by default 10 ºC / 50 ºF. Cooling mode:
29 to 35,5 ºC / 84 to 96 ºF, by default 35 ºC / 95 ºF.
•
Weight. This option is used to set the weight of each zone for purposes of determining
system operation. The weight of the zone will be used for calculating the mode (auto-
change over) or for calculating heat demands when using auxiliary heat. Options: Auto or
Manual.
o Auto. (By default). The weight of each zone is automatically assigned based on the
number of zones.
o Manual. Enables to manually define the weight of each zone. Values: 0 to 100.
•
Reset thermostat. (Not available in remote zones). This allows you to reset the thermostat
by returning to the initial settings menu.
EN