AIRZONE LITE
Select
the
zone
associated
thermostat by raising the microswitch
corresponding to the zone.
Select other control outputs associated
to the zone if necessary. The zone address
will be the one with the lowest number
selected (for example, associated output 6
to the zone address 5).
Wireless Lite
to
this
Open the wireless association channel. To
do so, click SW1. Once opened, you have
15 minutes to perform the association.
You can also open the wireless association
channel
thermostats.
IMPORTANT:
more than one channel open in the same
installation at the same time.
If you want to configure other thermostat
settings,
advanced settings menu from an Airzone
Blueface zero thermostat.
The icon
indicate that the association is correct. If
the icon blinks once in red, this indicates
that the zone is occupied, and if it blinks
twice in red, it means that the thermostat
is not in signal range.
Remember: Should it be necessary to
change the zone number, first reset the
thermostat and initiate the association
sequence.
through
the
Blueface
Remember
not
you
must
access
the
will blink 5 times in green to
EN
SW1
zero
to
have
zone
15