Insulation Tester with Multimeter / English
Store capacitance
2000
Enclosure
Double molded, waterproof
Shock (Drop Test)
6.5 ft. (2 meters)
Test current of 0.9 mA maximum, open circuit voltage 2.8 V
Diode Test
dc typical
Audible signal will sound if the resistance is less than 35Ω(
Continuity Check
approx.), test current <0.35 mA
PEAK
Captures peaks >1ms
Temperature Sensor Requires type K thermocouple
Input Impedance
>10 MΩ V dc & >9 MΩ V ac
AC Response
True rms
The term stands for "Root-Mean-Square," which represents
the method of calculation of the voltage or current value.
Average responding multimeters are calibrated to read
AC True RMS
correctly only on sine waves and they will read inaccurately
on non-sine wave or distorted signals. True rms meters read
accurately on either type of signal.
ACV Bandwidth
50 Hz to 1000 Hz
≤3 at full scale up to 500 V, decreasing linearly to ≤1.5 at
Crest Factor
1000 V
Display
40,000 count backlit liquid crystal with bargraph
Overrange Indication "OL" is displayed
Auto Power Off
15 minutes (approximately) with disable feature
Automatic (no indication for positive); Minus (-) sign for
Polarity
negative
Measurement Rate
2 times per second, nominal
Low Battery
"
" is displayed if battery voltage drops below operating
Indication
voltage
Battery
One 9 V (NEDA 1604) battery
24
All manuals and user guides at all-guides.com
25/01/2018 Version No. 001
25/01/2018 Version No. 001
Insulation Tester with Multimeter / English
mA, μA ranges; 0.5 A/1000 V ceramic fast blow A range; 10
Fuses
A/1000 V ceramic fast blow
Operating
41ºF to 104ºF (5ºC to 40ºC)
Temperature
Storage Temperature -4oF to 140oF (-20oC to 60oC)
Max 80% up to 87ºF (31ºC) decreasing linearly to 50% at
Operating Humidity
104ºF (40ºC)
Storage Humidity
<80%
Operating Altitude
7000 ft. (2000 meters) maximum.
This meter is intended for origin of installation use and
protected, against the users, by double insulation per EN61010-
1 and IEC61010-1 2nd Edition (2001) to Category IV 600V and
Safety
Category III 1000V; Pollution Degree 2. The meter also meets
UL 61010-1, 2nd Edition (2004), CAN/CSA C22.2 No. 61010-1
2nd Edition (2004), and UL 61010B-2-031, 1st Edition (2003)
25