PREPARING THE INSTALLATION LOCATION
IMPORTANT INSTALLATION INFORMATION
• All electric cooktops run off a single phase, three-
wire or four-wire cable, 240/208 volt, 60 hertz,
AC-only electrical supply with ground.
• Minimum distance between cooktop and
overhead cabinetry is 30" (762 mm).
I
30" Min.
(762 mm)
E
G
L
LCE3681ST Radiant Cooktop
Unit
B
A
Inch
36-11/16
22
3-3/4
mm
932
559
All dimensions are stated in inches and millimeters (mm).
Allow 2" (50 mm) space below the armored cable opening to clear the electric cable and allow space
for installation of the junction box on the wall at the back of the cooktop.
** Do not obstruct these areas!
A
K
F
C
D
E
Min
33-27/32
19-25/32
34-9/16
20-3/8
95
860
502
878
• Make sure the cabinets and wall coverings
around the cooktop can withstand the
temperatures (up to 93˚C [200˚F]) generated by
the cooktop.
36 inch Radiant Cooktop
B
D
H
F
4" X 8" (102 mm x 203 mm)
opening to route armored
cable if panel is present.
G
I
J
H
Min
Max
Min
13/16
13
5-23/32
517
20
330
145
C
J
K
L
2-1/2
24
64
610
23