safety information (continued)
ELECTRICAL CONNECTION
A 15-Amp, 120-Volt, 60 Hz circuit with a properly grounded outlet is required. Preferably, the item will be on a
dedicated circuit, as other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow
when the heater is in operation. The unit comes standard with a 6 ft. (1.8 m) long three wire cord, exiting the right
side of the item. Plan the installation to avoid the use of an extension cord. Extension cords are for temporary use
only. If an extension cord must be used, it must be UL/CSA certified, rated at 15A (1,875W), 125V maximum with 14
AWG minimum and constructed of two current carrying conductors with ground. A heavy duty extension cord with the
shortest length possible for the connection is recommended and must not be longer than 50 ft. (15.2 m). Do not coil or
cover the extension cord.
WarninG: Electrical outlet wiring must comply with local
building codes and other applicable regulations to reduce
the risk of fire, electrical shock and injury to persons.
WarninG: Do not use this fireplace if any part of it has
been under water. Immediately call a qualified service
technician to inspect the fireplace and replace any part of
the electrical system which has been under water.
GROUNDING INSTRUCTIONS
This heater is for use on 120 volts. The cord has a plug as shown at (A) in Figure 1. An adapter as shown at (C) is
available for connecting three-blade grounding-type plugs to two-slot receptacles. The green grounding lug extending
from the adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter
should not be used if a three-slot grounded receptacle is available.
GROUNDING
PIN
(C)
All manuals and user guides at all-guides.com
danGer
Figure 1
(a)
METAL SCREW
COVER OF GROUNDED
OUTLET BOX
ADAPTER
GROUNDING
GROUNDING
MEANS
PIN
(B)
NOTE:
(d)
4
Adapters are NOT
for use in Canada.