Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.
Specifications
• Max. flow
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
Scalding protection possible by fitting a handle
rotation stop (order no. 46 308).
• Water connection
• Non reversible cartridge
Note:
Major pressure differences between cold and hot
water supply should be avoided.
Installation
Flush pipes thoroughly!
Mount faucet on basin
See dimensional drawing fold-out page I.
- Place seal (A) on basin and insert faucet
with hoses (B) through the holes of the basin,
see fig. [1].
- Screw on counter unions (C) with gasket (D) from
below.
- Tighten hexagon nut with a 13mm socket wrench.
Mount lift rod and pop-up drain
- Insert the lift rod part with the knob (E) through the
body and screw on the lower part (F), see fig. [2].
- Fit pop-up drain (28 957), see fold-out page II,
ensure that flange of pop-up drain is sealed.
Connect faucet
For this purpose the supply hoses must be connected
to the angle stops (or other supply points), see figs. [1]
and [2].
The cold water supply should be connected on the
right, the hot water supply on the left side.
Avoid cross connection. The cartridge is not
reversible.
8.3 L/min o 2.2 gpm / 60 psi
7.25 psi
14.5 - 72.5 psi
145 psi
232 psi
176 °F
cold - RH
hot - LH
English
Open angle stops and check faucet for correct
function, see fig. [4].
Lift lever
Press lever down
Move lever to right
Move lever to left
Check connections for leakage.
Flow rate limiter
This mixer is fitted with a flow rate limiter, permitting an
infinitely individual variable reduction in the flow rate.
The highest possible flow rate is set by the factory
before despatch. The use of flow rate limiters in
combination with hydraulic instantaneous water
heaters is not recommended.
For commissioning see "Replacing the cartridge"
point 1 to 3, fig. [5] and [6].
Maintenance
Inspect and clean all parts, replace as necessary and
grease with special grease.
Shut off the hot and cold water supply!
I. Replacing the cartridge, see fig. [5].
1. Remove cover cap (G).
2. Remove screw (H) and pull off lever (J).
3. Remove cap (K).
4. Remove screws (L) and detach complete
cartridge (M).
5. Replace complete cartridge (M).
Assemble in reserve order.
Observe the correct installation position!
Make sure that the cartridge seals engage in the
grooves on the housing. Fit screws (L) and tighten
evenly and alternately.
II. Unscrew and clean flow regulator (13 955), see
fold-out page II.
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this faucet will be found in the
Limited Warranty supplement.
= open (water flow)
= closed (off)
= cold water
= hot water