After having carried out the various connections and having supplied voltage, all the
LEDS are switched off.
The motor opens and closes, but it has no strength and moves slowly.
The gate opens but does not close after the time set.
The gate does not open or close by activating the various K and RADIO buttons.
By activating the K button the gate does not move.
The slowing phase is not performed.
ACCESSORIES
For the connections and the technical data of the optional equipments follow the relevant handbooks.
RADIO TRANSMITTER SUN
SUN 2CH
code ACG6052
SUN CLONE 2CH
code ACG6056
FIT SIX EN12978 - EN13849-2
to embed - range 15/30 m
FAULT
SUN 4CH
code ACG6054
SUN CLONE 4CH
code ACG6058
code ACG8049
Check the integrity of fuses F1 and F2. In case of interrupted fuse use only of adequate value
F2 = 5A F1 = 100mA.
Check trimmers TORQUE and LOW-SPEED adjustment.
Ensure to have set DIP 3 to ON.
Button K BUTTON always inserted in automatic functioning mode (DIP 6 OFF). Replace button or switch
of the selector switch.
Failed edge self-test => check the connections between electronic board and edge feeder.
Attention: if not using a feeder for edges, DIP 10 must be OFF.
Faulty safety edge contact. Faulty photocells contact with DIP 4 OFF.
Fix or replace the relative contact.
Impulse K always inserted. Check and replace any buttons or micro-switches of the selector switch.
Ensure that DIP 8 is set OFF (slowing enabled).
Learn the times through procedure from DIP 2.
Check trimmer LOW-SPEED adjustment.
S18
S18 to embed (NO+NO)
code ACG1054
S18 to wall (NO+NO)
code ACG1056
FIT SLIM EN12978 - EN13849-2
PHOTOCELLS for the wall-installation
PAIR OF COLUMNS FOR FIT SLIM
FIT SLIM photocells have synchronism function in AC current and ranges of 20 m.
You can fit many couples close together thanks to the synchronising circuit.
Add the SYNCRO TRANSMITTER TX SLIM SYNCRO code ACG8029B for more than 2 photocells
couples (up to 4).
24
SOLUTION
S18 to embed (NO+NC)
S18 to wall (NO+NC)
code ACG8032B
code ACG8065
code ACG1054S
code ACG1056S