Télécharger Imprimer la page

TDK-Lambda DPX Serie Mode D'emploi page 13

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
Product HANDBOOK
General Safety Instructions:
A suitable mechanical and fire enclosure must be provided by the end use equipment for mechanical and fire
hazard protection.
Environmental Specifications:
Description
Use
Temperature
Humidity
Pressure
Shock
Vibration
Material Group
Pollution Degree
Overvoltage Category
Class
Product data:
Product
DPX15W Series
DPX20
DPX20W Series
DPX30
DPX30W Series
DPX40
DPX40W Series
DPX60
* With derating (see product datasheet for derating curves).
Storage temperature all DPX: -40° C to +105°C
Isolation voltage
Dielectric Strength testing is carried out as follows:
Input to output: 1600Vdc
Input (Output) to chassis: 1600Vdc
Safety Approvals:
CE marking when applied to any DPX product, indicates compliance with the Low Voltage Directive
(2006/95/EC) in that it complies with EN60950-1: 2
Fusing: The products are internally fused and protected against reverse input polarity (see input parameters
table below)
Symbols:
DC
DPX Series
Operation
Indoor
See product data below
5 to 95% RH, non-condensing
70kPa - 106kPa
Operation temperature without derating
-40° C to +85° C
-40° C to +76° C
-40° C to +78° C
-40° C to +70° C
-40° C to +67° C
-40° C to +69° C
-40° C to +66° C
-40° C to +60° C
nd
Edition
See product data below
5 to 95% RH, non-
MIL-STD-810F
MIL-STD-810F
IIIb
2
II
I
Operation temperature with derating *
+85° C to +95° C
+76° C to +94° C
+78° C to +91° C
+70° C to +94° C
+67° C to +90° C
+69° C to +90° C
+66° C to +87° C
+60° C to +85° C
Storage
-
condensing
54kPa - 106kPa

Publicité