FAULT FINDING CHART
PROBLEM
The monitor does not switch
on.
The monitor switches on but
the motor fails to start.
Walking motion is jerky on
the treadmill.
The machine stops (the
breaker trips).
Electrical shocks through
the handrail.
The treadmill belt skews off
centre.
CHECKS
1) Make sure that the
machine is plugged in, the
ON/OFF switch in position 1
and that the safety key is
inserted.
2) Check that the current
limiter is pressed in.
3.a) Check that the belt is
lubricated.
3.b) Check the tension on
the sliding belt.
3.c) Check the tension on
the drive belt.
4) Check that the band is
lubricated.
5) Check that the machine
is plugged into an earthed
mains socket.
6.a) Check that the machine
is level on the floor.
6.b) Check that the machine
does not wobble.
19
SOLUTIONS
1) Plug the machine into the
mains
supply.
switch to position 1 and
insert the safety key.
2) Switch the machine off
and
press
the
breaker in. Lubricate the
treadmill band.
3.a) Lubricate the sliding
belt.
3.b) Adjust the belt tension.
3.c) Adjust the drive belt
tension.
4)
Reset
the
button with the On /Off
switch at „0" and lubricate
the treadmill band.
5) Plug the machine into an
earthed mains socket.
Set
the
circuit
overload

Publicité

loading