WARNINGS AND CAUTIONS:
• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!
• TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
• IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT AN ELECTRICIAN.
• THIS DEVICE IS NOT A LIGHTNING ARRESTOR. IT WILL NOT SURVIVE LIGHTNING STRIKES IN CLOSE PROXIMITY TO THE PREMISES.
• INSTALL THIS DEVICE ONLY ON A SINGLE BRANCH CIRCUIT PROTECTED BY A FUSE OR A CIRCUIT BREAKER.
• USE THIS DEVICE WITH COPPER OR COPPER CLAD WIRE ONLY.
• A SURGE PROTECTIVE RECEPTACLE WILL PROVIDE MAXIMUM PROTECTION FOR LOADS PLUGGED DIRECTLY INTO IT. IT WILL PROVIDE SOME PROTECTION TO DOWNSTREAM RECEPTACLES, THOUGH PROTECTION
DIMINISHES PROPORTIONALLY WITH THE LENGTH OF WIRE RUN.
• FOR CAT. NOS. 5280, 5380, 7280, 7380, 8280, 8380 & 8381 ONLY: DO NOT INSTALL THIS DEVICE IF THERE IS NOT AT LEAST 10 METERS (30 FEET) OR MORE OF WIRE BETWEEN THE ELECTRICAL OUTLET AND THE
ELECTRICAL SERVICE PANEL.
INSTALLATION
1A. INSTALLING A SURGE PROTECTIVE RECEPTACLE AT THE END OF LINE (Wiring Diagram A): TURN OFF POWER to this receptacle by removing the fuse or turning the circuit breaker OFF.
1B. INSTALLING A SURGE PROTECTIVE RECEPTACLE IN PLACE OF A RECEPTACLE IN A FEED-TROUGH BRANCH CIRCUIT (Wiring Diagram B): Select the receptacle which will be replaced by the Surge Protective Receptacle TURN
OFF POWER to this receptacle by removing the fuse or turning the circuit breaker OFF.
2.
Use a test lamp to confirm that BOTH outlets are NOT powered.
3.
Remove existing wallplate and receptacle, if applicable.
4.
Remove all wires on SILVER colored terminal screws of old receptacle (should be WHITE Neutral conductors).
a) For Side Wiring: Remove insulation 5/8" (1.6 cm). Wrap this short wire 3/4 turn clockwise around the terminal screw marked "WHITE WIRE". Tighten the terminal screw securely.
b) For Back Wiring: Remove insulation 1/2" (1.3 cm). Insert this short straight wire into hole marked "WHITE WIRE". Tighten the terminal screw securely. Be sure the terminal clamp tightens on the conductor only, not the insulation.
5.
Remove all wires on BRASS colored terminal screws of old receptacle (should be BLACK or RED Hot conductors).
a) For Side Wiring: Remove insulation 5/8" (1.6 cm). Wrap this short wire 3/4 turn clockwise around the terminal screw marked "HOT WIRE". Tighten the terminal screw securely.
b) For Back Wiring: Remove insulation 1/2" (1.3 cm). Insert this short straight wire into hole marked "HOT WIRE". Tighten the terminal screw securely. Be sure the terminal clamp tightens on the conductor only, not the insulation.
6.
Disconnect the conductor from the GREEN colored grounding screw on the old receptacle and connect it to the GREEN colored screw on the Surge Protective Receptacle. For Isolated Ground (IG) circuits using the -IG Surge Protection
Receptacles, re-connect the IG wire to the GREEN IG screw located on the end of the receptacle. A non-isolated building ground conductor (if available) should NOT be connected to this IG terminal because it will compromise the integrity of
the Isolated Ground. The non-isolated ground conductor (if available) should be connected to the metal wallbox.
7.
Installation may now be completed by carefully positioning all wires to provide room in outlet box for receptacle. Mount the Surge Protective Receptacle in wall box, with the ground contact upwards, using the two long mounting screws
supplied. Attach wallplate.
8.
Restore power at circuit breaker or fuse. INSTALLATION IS COMPLETE.
OPERATION
Leviton's Surge Protective Receptacles are designed to reduce the random energy surges of voltage transients and electrical noise on the power supply line.
Leviton's Surge Protective Receptacles can be used to protect sensitive electronic equipment in industrial, commercial and residential locations from the stress and degradation inflicted by voltage transients.
Isolated Ground (-IG) Surge Protective Receptacles provide a pure grounding path isolated from the normal grounding means which employs the unit's mounting strap.
Hospital Grade and Commercial Grade Surge Protective Receptacles have an audible tone alarm. If transient protection is lost, the alarm will sound and the green LED indicator light will go out. The alarm tone can be silenced by turning
counterclockwise the small screw located on the face of unit, beneath the alarm label. Tamper Resistant Receptacle alarm tone can be silenced by removing the alarm seal and depressing the alarm button. Hospital Grade receptacles are
identified by a GREEN dot on the device face.
The diagnostics LED indicator light is ON continuously when protection is active, but turns OFF when protection circuit is deactivated due to excessive transients. The entire unit must be replaced if surge protection is required. If the unit is not
replaced, it will function only as a conventional receptacle within its given rating.
Tamper Resistant Surge Protective Receptacles have a shutter mechanism inside the receptacle that blocks access to the contacts unless a two-prong plug is inserted, helping to ensure that hairpins, keys, etc. will be locked out.
Wiring Diagram A
Schéma de câblage A
Diagrama de Cableado A
Surge Protective Receptacle
Prise protecteur de surtensions
Receptáculo Protector de Sobrecargas
Hot (Black)
Actif (Noir)
Fase (Negro)
Line / Ligne / Línea
125V AC/CA, 50/60 Hz
Neutral (White)
Neutre (Blanc)
Neutro (Blanco)
FOR CANADA ONLY: For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada ULC to the attention of the Quality Assurance Department, 165 Hymus Blvd,
Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton's only obligation is to correct
such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an
improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for
a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential
damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
REMARQUE : les numéros de modèle commençant par un « T » indiquent que la prise est dotée d'un mécanisme d'inviolabilité.
AVERTISSEMENTS ET MISES EN GARDE :
• POUR ÉVITER LES RISQUES D'INCENDIE, DE CHOC ÉLECTRIQUE OU D'ÉLECTROCUTION, COUPER LE COURANT AU FUSIBLE OU AU DISJONCTEUR ET S'ASSURER QUE LE CIRCUIT SOIT BIEN COUPÉ AVANT DE
PROCÉDER À L'INSTALLATION.
• INSTALLER OU UTILISER CONFORMÉMENT AUX CODES DE L'ÉLECTRICITÉ EN VIGUEUR.
• À DÉFAUT DE BIEN COMPRENDRE LES DIRECTIVES SUIVANTES, FAIRE APPEL À UN ÉLECTRICIEN.
• CE DISPOSITIF N'EST PAS UN PARAFOUDRE; IL NE RÉSISTERA PAS AUX COUPS DE FOUDRE À PROXIMITÉ DES LIEUX QU'IL PROTÈGE.
• INSTALLER CE DISPOSITIF UNIQUEMENT SUR UN CIRCUIT SIMPLE PROTÉGÉ PAR UN FUSIBLE OU UN DISJONCTEUR.
• N'UTILISER CE DISPOSITIF QU'AVEC DU FIL DE CUIVRE OU PLAQUÉ CUIVRE.
• LES PRISES À DISPOSITIF LIMITEUR DE SURTENSIONS OFFRENT UNE PROTECTION MAXIMALE AUX CHARGES QUI LEUR SONT DIRECTEMENT ENFICHÉES; ELLES PROTÈGENT CEPENDANT LES PRISES EN AVAL, MAIS LE
NIVEAU DE PROTECTION EST INVERSEMENT PROPORTIONNEL À LA LONGUEUR DU PARCOURS DE FIL.
• NOS DE CAT. 5280, 5380, 7280, 7380, 8280, 8380 ET 8381: NE PAS INSTALLER CET DISPOSITIF S'IL N'Y A PAS AU MOINS 10 MÈTRES (30 PIEDS) OU PLUS DE FIL ENTRE LA PRISE ÉLECTRIQUE ET LE PANNEAU DE
SERVICE ÉLECTRIQUE.
INSTALLATION
1A. INSTALLATION DE LA PRISE PROTECTEUR DE SUR TENSIONS EN FIN DE CIRCUIT (Schéma de câblage A) : Couper l'alimentation alimentationalimentation de cette dernière en retirant le fusible ou en mettant le disjoncteur à la
position «0».
1B. INSTALLATION DE LA PRISE PROTECTEUR DE SUR TENSIONS EN REMPLACEMENT D'UNE AUTRE SUR UNE DÉRIVATION DE PASSAGE (Schéma de câblage B) : Choisir la prise à remplacer; couper l'alimentation de cette
dernière en retirant le fusible ou en mettant le disjoncteur à la position «0».
2.
Utiliser une lampe de vérification pour s'assurer que les DEUX parties de la prise soient bien HORS tension.
3.
Retirer la plaque murale et le prise existant, le cas échéant.
4.
Retirer tous les fils raccordés à la vis ARGENT de l'ancien prise (conducteurs neutres BLANCS).
a) Câblage latéral : dénuder sur 1,6 cm (5/8 po); enrouler le fil 3/4 de tour vers la droite sur le borne de «FIL BLANC»; serrer fermement la vis.
b) Câblage arrière : dénuder 1,3 cm (1/2 po); insérer le fil dans l'orifice de «FIL BLANC»; serrer fermement la vis; s'assurer que le borne de serrage soit appuyée sur les fils seulement, pas sur l'isolant.
5.
Retirer tous les fils raccordés à la vis LAITON de l'ancien prise (conducteurs actifs NOIRS ou ROUGES).
a) Câblage latéral : dénuder sur 1,6 cm (5/8 po); enrouler le fil 3/4 de tour vers la droite sur le borne de «FIL ACTIF»; serrer fermement la vis.
b) Câblage arrière : dénuder 1,3 cm (1/2 po); insérer le fil dans l'orifice de «FIL ACTIF»; serrer fermement la vis; s'assurer que le borne de serrage soit appuyée sur les fils seulement, pas sur l'isolant.
6.
Retirer le fil de terre raccordé à la vis de terre de l'ancien prise et le raccorder à la borne VERT du le prise protecteur de surtensions. Quand une prise à DLST et à MALT isolée est raccordée à un circuit dont la mise à la terre est aussi
isolée, on doit relier le fil de MALT isolée à la vis VERTE de MALT isolée située à l'extrémité de la prise. Si la mise à la terre de l'installation n'est pas isolée, on NE DOIT PAS la raccorder à cette vis, ce qui aurait pour effet de compromettre
l'isolation de la mise à la terre du dispositif; les fils de MALT non isolée doivent plutôt être reliés à la boîte murale métallique.
7.
Enfoncer délicatement les fils dans la boîte murale en prévoyant suffisamment d'espace pour le prise; installer ce dernier au moyen des vis d'assemblage fournies; fixer la plaque murale.
8.
Rétablir le courant au fusible ou au disjoncteur; L'INSTALLATION EST TERMINÉE.
Surge Protection Receptacles
Cat. Nos. 5280, T5280, and 5280-IG (Commercial Grade)
Cat. Nos. 7280, T7280, and 7280-IG (Commercial Grade w/Alarm)
Cat. Nos. 8280, T8280, and 8280-IG (Hospital Grade)
Cat. Nos. 5380, T5380, and 5380-IG (Commercial Grade)
Cat. Nos. 7380, T7380, and 7380-IG (Commercial Grade w/Alarm)
Cat. Nos. 8380, T8380, and 8380-IG (Hospital Grade)
NOTE: Part numbers beginning with the letter "T" indicate receptacle with tamper resistant mechanism.
Green Ground
Vert terre
Hot (Black)
Verde Tierra
Actif (Noir)
Fase (Negro)
Neutral (White)
Neutre (Blanc)
Neutro (Blanco)
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
For Technical Assistance Call: 1-800-824-3005 (USA Only) or 1-800-405-5320 (Canada Only) www.leviton.com
Prises à limiteur de surtensions transitoires
N
os
de cat. 5280, T5280 et 5280-IG (qualité commerciale)
N
de cat. 7280, T7280 et 7280-IG (qualité commerciale, avec avertisseur)
os
N
os
de cat. 8280, T8280 et 8280-IG (qualité hospitalière)
N
os
de cat. 5380, T5380 et 5380-IG (qualité commerciale)
N
os
de cat. 7380, T7380 et 7380-IG (qualité commerciale, avec avertisseur)
N
os
de cat. 8380, T8380 et 8380-IG (qualité hospitalière)
15A-125VAC, 50/60Hz
20A-125VAC, 50/60Hz
INSTALLATION INSTRUCTIONS
Receptacle
Prise
Receptáculo
Line / Ligne / Línea
125V AC/CA, 50/60 Hz
15A-125 V c.a., 50/60Hz
20A-125 V c.a., 50/60Hz
DIRECTIVES
Wiring Diagram B
Schéma de câblage B
Diagrama de Cableado B
Surge Protective Receptacle
Prise protecteur de surtensions
Receptáculo Protector de Sobrecargas
Green Ground
Green Ground
Vert terre
Vert terre
Verde Tierra
Verde Tierra
PK-93999-10-02-0E
ENGLISH
Receptacle
Prise
Receptáculo
Green Ground
Vert terre
Verde Tierra
FRANÇAIS

Publicité

loading

Sommaire des Matières pour Leviton 5280

  • Page 1 NIVEAU DE PROTECTION EST INVERSEMENT PROPORTIONNEL À LA LONGUEUR DU PARCOURS DE FIL. • NOS DE CAT. 5280, 5380, 7280, 7380, 8280, 8380 ET 8381: NE PAS INSTALLER CET DISPOSITIF S'IL N'Y A PAS AU MOINS 10 MÈTRES (30 PIEDS) OU PLUS DE FIL ENTRE LA PRISE ÉLECTRIQUE ET LE PANNEAU DE SERVICE ÉLECTRIQUE.
  • Page 2 • SOLO PARA LOS NO. DE CAT. 5280, 5380, 7280, 7380, 8280, 8380 Y 8381: NO INSTALE ESTE APARATO SI NO HAY AL MENOS 10 METROS (30 PIES) O MAS DE CABLE ENTRE EL CONTACTO ELECTRICO Y EL PANEL DE...

Ce manuel est également adapté pour:

T52805280-ig7280T72807280-ig8280 ... Afficher tout