Télécharger Imprimer la page

Atag VA2214MQ Notice D'utilisation page 137

Publicité

Les langues disponibles

Les langues disponibles

5. Turn the pump wheel located behind the drainage pump stop by hand. Carefully remove any
sharp items, such as glass.
6. Refit the drainage pump stop. Refit the filter.
7. Plug the machine in again.
NOTE!
Do not forget to refit the drainage pump stop.
Unblocking the inlet hose filter
If the water supply contains small particles, the outer filter on the inlet hose may become blocked,
which results in the Water inlet fault error message.
1. Turn off the machine using
2. Turn off the water tap.
3. Unscrew the inlet hose.
4. Carefully remove the outer filter from the inlet hose and clean it.
5. Refit the filter and check that the gasket is correctly positioned.
6. Screw the inlet hose firmly into place.
7. Plug the machine into the wall socket and turn on the water tap. Allow the pressure to settle for
a while and check that the connection is watertight.
Drainage pump
stop
and remove the plug from the wall socket.
Outer filter on
inlet hose
Gasket
Care and cleaning
23

Publicité

loading