Télécharger Imprimer la page

Sierra Flame AUSTIN-65G-NG-DELUXE Manuel D'installation Et Guide De L'utilisateur page 6

38,000 btu, gaz naturel et propane

Publicité

1.0 INTRODUCTION
1.1 SPECIFICATIONS
TABLE 1
ITEM
MAXIMUM INPUT: Hi
MINIMUM INPUT: Lo
MANIFOLD PRESSURE:
COLLECTEUR DE PRESSION:
GAS INLET SUPPLY PRESSURE:
ENTREE DE PRESSION
ORIFICE SIZE: @ 0-4500'
FORMAT D'ORIFICE:
AIR SHUTTER
VOLET DE L'AIR
CONTROL VALVE TYPE:
TYPE DE SOUPAPE
VENTING
ÉVACUATION
FAN
VENTILATEUR
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING
CET APPAREIL DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LE TYPE DE GAZ INDIQUÉ SUR LA
NATURAL GAS (NG)
38,000 Btu/hr (11.14 kW)
27,000 Btu/hr (7.91 kW)
3.5" w.c. (0.87 kPa)
Minimum: 5.0" w.c. (1.2 kPa)
Maximum: 13.5" w.c. (3.4 kPa)
2 X # 45 DMS
OPEN 1/8"min
(3.175mm)
Skytech AF-40004
2-ply aluminum vent, Selkirk,
Duravent , Security Venting,
ICC Venting or
Metal-Fab Venting
Variable Speed (110 Volt / 60 Hz)
PLATE.
PLAQUE SIGNALÉTIQUE.
PROPANE (LP)
38,000 Btu/hr (11.14 kW)
26,000 Btu/hr (7.62 kW)
10.0" w.c. (2.49 kPa)
Minimum: 7.0" w.c. (1.74 kPa)
Maximum: 13.5" w.c. (3.4 kPa)
2 X # 56 DMS
FULLY OPEN
Skytech AF-40004
2-ply aluminum vent, Selkirk
Duravent, Security Venting,
ICC Venting or
Metal-Fab Venting
Variable Speed (110 Volt / 60 Hz)
Page 6 of 54

Publicité

loading