-
If the suction power decreases, turn the motor off using the switch and when the motor has
completely stopped, lift the lid (fig.1). Tilt the motor body as shown in figure 2. Beat the filter slightly to
drop the ash into the bin (fig.3). Then remove the filter from its housing maintaining the motor body in a
tilted position and turning it slightly.
-
Wash the filter under a gentle jet of running water (fig.4) and at room temperature in order not to damage
it. Use a soft brush to remove the most stubborn residues. Do not use hot water otherwise the filter may
warp.
-
Do not use detergents. Leave the filter to dry naturally before replacing it in its housing. Do not place it
close to hot sources of heat. Do not place it in direct sunlight.
-
It is advisable, in any case, to clean a max. of 2/3 kg of ash during each cleaning operation. Operate the filter reset
lever, before each cleaning cycle.
-
When the stove or fireplace has been cleaned, the appliance and suction filter must then be cleaned as described
above. The cleaning operations should be done outdoors.
-
Position the steel pipe in fitting (fig.3) by jointing the connection supplied with the machine (fig.4) and turn the
appliance on using the switch. Direct the outlet of air towards the filter and, if necessary, shake the filter with the
metal nozzle located on the outside of the pipe.
-
Once the filter has been cleaned, check whether it is suitable for further use. If it has been damaged or broken,
replace it with an original Ribimex filter.
-
To take out the filter, remove it forcefully.
-
To insert the new filter, press on it as far as it will go.
PREFILTER SUPPLIED WITH THE EQUIPMENT:
-
Follow the instructions as indicated in the leaflet inside the package.
BLOWING FUNCTION (NOT AVAILABLE FOR THE MODEL PRCEN011/ PRCEN009 / PRCEN001)
To use the blowing function, insert the pipe in the air outlet hole as shown in fig. 3 when the equipment is switched
off and fit the connector shown in fig. 4 that is supplied with the equipment on the end of the pipe. Turn the ash
cleaner on using the switch.
CLEANING AND MAINTENANCE
CAUTION: Before carrying out any cleaning or maintenance operation, the plug must always be
The container and the filter should be cleaned quite regularly to ensure the equipment works properly. If the
equipment does not work satisfactorily, it may be due to the presence of residue or dirt inside the filter or the pipe. In
this case, it is advisable to turn off the equipment, remove the plug from the socket and then clean the parts.
If these instructions are not followed, the guarantee will automatically become null and void.
The only filter that can be cleaned - replaced by the user is filter group.
Filter must only be replaced by qualified staff.
removed from the socket.
fig.4