Nilfisk RS 851 Instructions D'origine page 130

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH
Hydraulic system data
Maximum drive system pressure
Suction fan system maximum pressure
Maximum accessory system pressure
Hydraulic system oil viscosity [at ambient temperatures above +50 °F (+10 °C)] (*)
Hydraulic system oil type
Brake fl uid type
(*)
If the machine is to be used at ambient temperatures below +50 °F (+10 °C), the oil should be replaced with equivalent oil
having a viscosity of 32 cSt. For temperatures below +32 °F (0 °C), use oil with lower viscosity.
(**)
See the hydraulic system oil technical data and reference data tables below.
(***)
See the brake fl uid technical data and reference data tables below.
AGIP ARNICA SPECIFICATIONS
Viscosity at +104 °F (+40 °C)
Viscosity at +212 °F (+100 °C)
Viscosity index
Flash point COC
Pour point
Density at +59 °F (+15 °C)
DOT4 SPECIFICATIONS
Viscosity at -40 °F (-40 °C)
Viscosity at +212 °F (+100 °C)
Dry boiling point
Wet boiling point
Density at +59 °F (+15 °C)
Colour
Climate control system data
Gas type
Gas quantity
Camera kit description (optional) (*)
Make
Type
(*)
For other data/values of the optional equipment, see the relevant Manuals.
14
USER MANUAL
mm
/s
2
mm
/s
2
/
°F (°C)
°F (°C)
kg/l
33018305(3)2010-01 A
46
32
45
32
7.97
6.40
150
157
419 (215)
395.6 (202)
-32.8 (-36)
-32.8 (-36)
0.87
0.865
mm
/s
1,300
2
mm
/s
2.2
2
°F (°C)
509 (265)
°F (°C)
338 (170)
kg/l
1.07
/
Yellow
RS 851
Values
4,351 psi (300 Bar)
3,046 psi (210 Bar)
1,595 psi (110 Bar)
46 cSt
AGIP Arnica 46 (**)
DOT4 (***)
Approvals and specifi cations
ISO-L-HV
ISO 11158
AFNOR NF E 48603 HV
AISE 127
ATOS Tab. P 002-0/I
BS 4231 HSE
CETOP RP 91 H HV
COMMERCIAL HYDRAULICS
Danieli Standard 0.000.001 (AGIP
ARNICA 22, 46, 68)
EATON VICKERS I-286-S3
EATON VICKERS M-2950
DIN 51524 t.3 HVLP
LAMB LANDIS-CINCINNATI P68, P69, P70
LINDE
PARKER HANNIFIN (DENISON) HF-0
REXROTH RE 90220-1/11.02
SAUER-DANFOSS 520L0463
Approvals and specifi cations
SAE J 1703
FMVSS 116 - DOT4&DOT3
ISO 4925
CUNA NC 956 DOT4
Values
Reclin 134a
1.76 lb (0.8 kg)
Values (*)
Continental VDO -
LCD 5" colour monitor
Infrared colour camera

Publicité

Table des Matières
loading

Table des Matières