Connecting the outdoors unit to the
indoors unit
Connect the two cooling pipes by screwing together
the threaded couplings. The threaded couplings are
self-closing valves which will not open until the
threaded couplings are screwed correctly together.
You can also disconnect the threaded couplings
again. In this case the valves will close automatically,
preventing no loss of coolant. Use two fork wrenches
to steady the cooling pipes against twisting.
Plug the condensation water pipe on the nipple of
the connection block. The condensation water pipe is
included in the pipe pack together with the cooling
pipe. In this same pack you will also find the plug
connector for connecting the outdoors unit to the
power supply.
Before starting up the appliance you must still fit the
rubber foot to the outdoors unit. This is only
necessary, however, if the outdoors unit is to be
placed on the ground.
14
30.10.2001 7:16 Uhr
Plug connector
Rubber
Screw
Rubber foo
Outdoors unit
Seite 14
Insert the rubber stopper in the socket at the back of
the outdoors unit if you have the outdoors unit
standing on the terrace where condensation water
escaping from the bottom of the outdoors unit causes
no problem and can simply be wiped away. If, on the
other hand, you have the outdoors unit hanging on
an outdoors wall, remove the rubber stopper and
fasten a drainage pipe to discharge the condensation
water.
Inside the outdoors unit there are two trays for
collecting the condensation water. Only when no
stopper is inserted will the condensation water
escape through the drainage socket.