FIL-PILOTE INTERFACE
Selected versions of SKT-3 are equipped with a FIL PILOTE inter-
face which enables remote heating control through an external
controller which conforms to FIL PILOTE standards. SKT-3 reacts
to all the 6 standard commands:
Signal
FP Command
Reaction of the Controller
Heating in accordance with current
FP-COMFORT
setting
Reduction of setting by 3°C (or 3 levels
FP-ECO
in heat output regulation mode)
No heating, anti-freeze function is active
FP-AF
(AF code shows on the display panel)
Heating mode and anti-freeze functions
FP-STOP
are both off (OF code shows on the
display panel)
Reduction of setting by 1°C (or 1 level in
FP-ECO1
heat output regulation mode)
3 s
300 s
Reduction of setting by 2°C (or 2 levels
FP-ECO2
in heat output regulation mode)
7 s
300 s
It is also possible to use the DRYER mode while the device reacts to
the FP commands – DRYER mode is superior, therefore the device
will work according to the DRYER'S parameters. It will return to
fulfilling FP commands on termination of the DRYER mode (see
– DRYER mode).
TROUBLESHOOTING
Problem
Possible cause
Device is connected to
Connection problem
electricity, LCD display
is blank
Device does not heat,
Temperature sensor
terror code (ie. E9) is
problem
flashing on the display
Possible incorrect
installation of controller
on the heating element
Device heats despite
Possible electronics
having been turned off
damage
with the
button
If the problem persists, please contact your local Distributor
User Manual — Electric heating elements of the SKT series
Problem solution
Check the power lead is
connected. Check if the
controller uptakes
correct voltage.
Disconnect the device
completely from
electricity and wait until
the radiator cools down.
Turn it back on again.
Check if the controller
has been correctly
installed on the heating
element (controller
casing should hide the
entire head of the
heating element).
Disconnect the device
completely from
electricity and wait until
the radiator cools down.
Turn it back on again.
57