DANGER! Slowly exhaust the system to avoid uncontrolled movements of the
system components.
3. Protect the system against being restarted (accident prevention).
4. Allow the product and adjacent system parts to cool down (accident preven-
tion).
5. Wear protective clothing (accident prevention).
6. Loosen and remove all connections.
7. Remove the flow sensor from the pressure connection using an open-end
wrench (thread connection) or pull it straight out of the push-in fitting.
11 Disposal
Improper disposal of the product and packaging will lead to pollution of the envi-
ronment. Furthermore, the materials can no longer be recycled.
Dispose of the product and the packaging in accordance with the applicable
u
national regulations.
12 Troubleshooting
If you cannot remedy a malfunction, get in touch with our contact address (con-
tact data. See back cover.
12.1 Basic requirements
General requirements for repair
• Never dismantle or convert the product (accident prevention, material pro-
tection).
• Do not carry out any unauthorized repair attempts (accident prevention, ma-
terial protection).
Permissible spare parts and reconditioning kits
• Only use spare parts and reconditioning kits from the online catalog (accident
prevention, material protection).
12.2 Notes on safety
To eliminate risks during troubleshooting, observe the notes on safety. See
g 2. Safety.
12.3 Procedure
Step 1: Check the system
In case of malfunctions, first check the system or the system part where the
u
product is installed. Check the following items:
• Are all connections connected to the product?
• Does the operating voltage comply with the requirements? See
cal
data.
• Does the operating pressure comply with the requirements? See
nical
data.
• Does the temperature comply with the requirements? See
data.
Step 2: Check the product
1. Make sure the system or system part is not under pressure or voltage (acci-
dent prevention, material protection).
2. Check the product based on the fault patterns described below. See
g 12.4 Malfunction
types.
3. Perform troubleshooting using the information under "Remedy".
4. Put the system or system part and product back into operation.
If you are unable to eliminate the malfunction as described under "Remedy": Dis-
assemble the product and send to the specified address. See back cover.
12.4 Malfunction types
Message
Classification
Memory Invalid
Error
No MQTT Connection Warning
AVENTICS™ AF2 | R412026496–BAL–001–AB | English
g 13. Techni-
g 13. Tech-
g 13. Technical
Description
Remedy
The sensor memory is
Replace the flow sen-
damaged.
sor
No connection possi-
ble to the MQTT bro-
ker.
Message
Classification
Simulation active
Info
Q1/2 Overtemp
Warning
Q1 Shortcut
Warning
Q2 Shortcut
Warning
Q2/a Overload
Warning
Q2/a OverTemp
Warning
Q2 PulseConfig
Warning
Qa Overload
Warning
Qa OverTemp
Warning
Flow low Info
Info
Flow high Info/Warn-
Info/warning
ing
Pressure low
Warning
Pressure high
Warning
Temperature low
Warning
Temperature high
Info/warning
Pressure low/high Er-
Error
ror
Temperature low/high
Error
Error
Energy Counter off -
Info
Air only
Voltage low for Q1/2
Info
Voltage low for Q2/a,
Info
Qa
Voltage low for IO-
Info
Link
Q1 Config out of
Info
Range
Q2 Config out of
Info
Range
Qa Config out of
Info
Range
Invalid Medium + Ref-
Warning
Cond
Supply Voltage too
Warning
low/high!
Description
Remedy
Simulation active
(output signal or
process variable)
Driver overload for
switch output Q1/Q2.
Short circuit at Q1
Short circuit at Q2
Q2/a: No current
• Check whether
flow.
line is properly
connected.
• Check whether
load resistance is
too high.
Q2/a: Overtempera-
• Ideal: load of 500
ture of the output
ohms
driver
• Check whether
ambient tempera-
ture is too high.
Implausible configu-
ration of the Q2 pulse
output
See Q2/a Overload
See Q2/a OverTemp
Info: MBE -5 %
• Info: Standard
MBE +5 %
• Warning: Ex-
tended MBE +5 %
Increase pressure
Reduce pressure
Increase the tempera-
ture to the specified
value. See
g 13. Technical data
Reduce the tempera-
ture to the specified
value. See
g 13. Technical data
Process pressure out-
side the permissible
pressure range
Temperature of the
process medium out-
side the permissible
temperature range
Medium = Air
Formula for energy
counter only stored
for air, therefore with-
out function
Adjust voltage to the
specified value. See
g 13. Technical data
Adjust voltage to the
specified value. See
g 13. Technical data
Adjust voltage to the
specified value. See
g 13. Technical data
Switching points pa-
rameterized outside
the measurement
range
Switching points pa-
rameterized outside
the measurement
range
Switching points pa-
rameterized outside
the measurement
range
RefCond only valid for
air
Adjust voltage to the
specified value. See
g 13. Technical data