DIMENSION GUIDE
Electrical Requirements - U.S.A.
Only
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or
electrical shock.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code,
ANSI/ NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
Electrical Connection
Check local codes and consult gas supplier. Check existing
electrical supply and gas supply. See "Gas Supply Requirements"
section.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
■ Range must be connected to the proper electrical voltage and
frequency as specified on the model/serial/rating plate. The
model/serial/rating plate is located behind the oven door on
the top right-hand side of the oven frame.
A.
Model/serial/rating plate (located behind the oven door on the top
right-hand side of the oven frame)
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation Guide before
selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All KitchenAid
appliances are appropriately UL, CUL or CSA approved.
®
A
■ This range is manufactured with a 4-wire power supply cord
rated at 240 V, 40 A, rated at 194°F (90°C) and investigated for
use with this range.
Range Rating*
120/240 V
120/208 V
8.8-16.5 kW
7.8-12.5 kW
16.6-22.5 kW
12.6-18.5 kW
*The NEC calculated load is less than the total connected load
listed on the model/serial/rating plate.
**If connecting to a 50 A circuit, use a 50 A rated cord with kit.
For 50 A rated cord kits, use kits that specify use with a nominal
1
3
"(3.5 cm) diameter connection opening.
8
■ When a 4-wire, single phase 240 V, 60 Hz, AC only electrical
supply is available, a 40 A minimum circuit protection is
required on 30" (76.2 cm) ranges, fused on both sides of the
line.
■ A time-delay fuse or circuit breaker is recommended.
■ This range is equipped with a UL or CSA International
Certified Power Cord intended to be plugged into a standard
14-50R wall receptacle. Be sure the wall receptacle is within
reach of range's final location.
■ Do not use an extension cord.
■ The wiring diagram is located on the back of the range or in a
clear plastic bag.
4 of 15
Specified Rating
of Power Supply
Cord Kit and
Circuit Protection
Ampere
40 or 50**
50