Télécharger Imprimer la page

3M Secure Click FF-800 Serie Mode D'emploi page 8

Publicité

Les langues disponibles

Les langues disponibles

NIOSH
Particulate Filters
Approvals
P100
P95
X
X
X
N95
HF
X
Nuisance level relief**
Acid gases
X
X
Organic
X
vapors
*3M recommended for ozone protection up to 10 times the OSHA PEL or applicable government occupational exposure
limits, whichever is lower. NOTE: not NIOSH approved for use against ozone.
**3M recommended for relief against nuisance levels of acid gas or organic vapors. Nuisance level refers to concentrations
not exceeding OSHA PEL or applicable exposure limits, whichever is lower. Do not use for respiratory protection against
acid gas/organic vapors (except hydrogen fluoride for the D3076HF and D9093C).
Cartridge and Filter Selection and Approvals
Failure to properly dispose of spent cartridges, filters, or respirators contaminated by hazardous materials can result in per-
sonal exposures as well as environmental harm. Handling, transportation and disposal of spent cartridges, filters, or respira-
tors must comply with all applicable federal, state, and local laws and regulations.
3M™ Cartridges D8000 Series should be used before the expiration date on the cartridge packaging. The useful service life
of these cartridges will depend upon the activity of the wearer (breathing rate) specific type, volatility, and concentration of
contaminants and environmental conditions such as humidity, pressure, and temperature. Cartridges must be replaced in
accordance with an established change out schedule, regulations or earlier if smell, taste or irritation from the contaminant is
detected. Please see 3M Service Life Software at www.3m.com/SLS.
Particulate filters must be replaced if they become damaged, soiled or if increased breathing resistance occurs. N-series
filters should not be used in environments containing oils. R-series filters may be limited to 8 hours of continuous or
intermittent use if oil aerosols are present. In environments containing only oil aerosols, P-series filters should be replaced
after 40 hours of use or 30 days, whichever is first.
REPLACEMENT PARTS INSTRUCTIONS
3M™ Secure Click™ Full Facepiece FF-800 Series
The facepiece assembly consists of the head harness assembly, nose cup assembly, speaking diaphragm assembly,
exhalation valve assembly, lens, faceseal (small, medium or large), lens frame assembly (frame, nuts and screws), inhalation
valve assembly and exhalation valve cover assembly.
Exhalation Valve Cover Replacement
1.
Remove valve cover by gently pulling left and right side of cover away from the facepiece (Fig. 12 and 13).
2. Replace valve cover by aligning the cover over one side of the cartridge/filter adapter and pressing gently toward the
facepiece until the cover "snaps" in place. Repeat for other side.
Exhalation Valve Assembly Replacement
1.
Remove exhalation valve cover by gently pulling left and right side of cover away from the facepiece (Fig. 12).
2. Remove exhalation valve assembly by turning counter clockwise 1/4 turn (Fig. 14).
3. Replace exhalation valve assembly by aligning lugs with exhalation valve assembly opening in lens and turning clockwise
1/4 turn until firm stop.
4. Replace exhalation valve cover assembly.
Exhalation Valve Replacement
1.
Remove exhalation valve cover by gently pulling left and right side of cover away from the facepiece (Fig. 12).
2. Remove exhalation valve assembly by turning counter clockwise 1/4 turn (Fig. 14).
3. Grasp valve and pull each valve stem out from valve seat.
4. Inspect valve seat making certain it is clean and in good condition.
X
X
X
X
X
X
X
X
X
X
X
X
CAUTION
EN

Publicité

loading