Installation Instructions – LSRWM2B / LSSQWM2B Commercial LED Rough-In
INSTALLATION
Wall Mount Section
1.
Install wall mounting plate to splice box using splice
box hardware (provided by others) and tighten to
17 IN/LBS torque when using 8-32 screw (Figure 1).
2.
Wire unit per appropriate Wiring Diagram (refer to
electrical section).
3.
Attach rear wall mount tether to splice box mounting
screw (see Figure 2).
4.
Mount cylinder housing assembly to wall by tightening
screws on top and bottom of arm base to 17 IN/LBS
torque to engage mounting plate (Figure 3).
5.
Installer must apply silicone compound around entire
perimeter of the mounting arm where it mates to the
mounting surface.
Trim
1.
Insert trim into the opening of the LED module until it
is flush against the cylinder (for round cylinders) or flush
against the square trim plate (for square cylinders).
Splice Box
Figure 1
2
Wall Mount
Plate
Installation Instructions – LSRWM2B / LSSQWM2B Commercial LED Rough-In
IB520120ML
Attach To
Splice Box
Figure 2
Tighten
Screws
Figure 3