Konica Minolta Bizhub 184 Manuel D'installation page 4

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

VII. Loading the Developer
1. While pressing the connector tabs, push out the
connector from the imaging unit.
Tabs
2. Unscrew the screws that secure the PC drum
unit, and then take out the PC drum unit by
slightly opening the lower part (the shadowed
area) of the PC drum unit (five screws).
Note:
• Do not open the lower part wide, otherwise the
charger may drop.
• Do not touch or scratch the PC drum.
• Cover the PC drum unit, which has been
removed, with a protective cloth or similar mate-
rial.
Developing unit
A0XXIXC040MA
PC drum unit
A0XXIXC013MA
E-4
3. Remove the
developing
screws).
4. Ready a packet of the developer and cut off one
corner of the aluminum packet with scissors.
5. While turning the gear in the direction of the
arrow, pour the developer evenly into the devel-
oper chamber.
Note:
• Turn the magnet roller in the direction of its nor-
mal rotation, and not the backward.
• Be sure not to let the developer get inside the
collar.
6. Reinstall the developing unit cover, ensuring that
its tabs are fitted properly into the slits (three
screws).
Note:
Do not tilt the developing unit or imaging unit after
the developer is poured.
Temporarily tighten the screw first.
unit
cover
(three
A11UIXC014MA
Collar
A11UIXC015MA
A11UIXC016MA

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bizhub 164

Table des Matières