7
2
6
N.B.: Always cover the spa (except when mixing chemical ad-
ditives!) with the insulating cover, so as to reduce heating times
and thus minimize operating costs.
The time required for initial heat-up will vary depending on the start-
ing water temperature.
WARNING!
Do not get in the spa until the quantity of disinfectant has not
dropped below the level recommended by the manufacturer and/or
by your retailer.
Always check water temperature carefully before entering spa.
Control Panel
B
A
C
D
Control panel for models with 2 pumps.
A. CLEARRAY™ (
) Button: Manually activates the CLEAR-
RAY™ system for a one-hour period.
B. CLEARRAY™ Indicator Light: Lit when the CLEARRAY™ sys-
tem is on. Flashing when the UV bulb needs to be replaced.
C. Light On/Off (
) Button Options: Turns waterfall light,
footwell light, lighted cup holders and backlit pillows on in uni-
son. Press once for high intensity; press a second time for medi-
um intensity; press a third time for low intensity; press a fourth
time to turn off. The displayed color is changed using the light
mode button (D) below.
D. Light Mode (
) Button: Selects one of 4 light color modes
for waterfall, footwell, cup holders, and pillow lights.
E. Cooler (
) Button: Decreases water temperature set point.
Also used to navigate through the programming menus.
11
4
1
3
10
8
K
J
I
E
F
G
1
2
1 Electrical box
2 Power supply entrance(s)
3
1
Speed Pump (pump 1)
4 Heater
5 Drain valve
6 Pump drain plug(s)
9
7 1-Speed pump (pump 2)
8 Circulation pump
2
9 CLEARRAY™ (Ultraviolet) Water Purification System
5
6
10 Electronic Ballast (for the CLEARRAY™ System)
11 Display
F. Warmer (
Also used to navigate through the programming menus.
G. Jets 1 (
once to turn pump #1 on; press a second time to turn pump #1 off.
H. Jets 2 (
385): Turns jets pump #2 on and off. Press once to turn pump #2
on; press a second time to turn pump #2 off.
I. Menu (
menus.
J. Heat Indicator: Lit when heater is on.
K. LED Display: Can display current water temperature (default
display), water temperature set point, selected menu functions,
and error messages.
Operation Details
Temperature Adjustment: 65 to 104°F (18 to 40°C). Factory default
setting is 100°F (38°C).
H
CLEARRAY™ Operation: System runs for 1 hour (when manually
activated), then automatically shuts off.
Light Operation: All LED lights run for 2 hours, then automatically
shut off.
Jets 1/Jets 2 Button Operation: Jets run for 20 minutes when ac-
tivated, then turn off automatically to conserve energy. Simply
press either jets button to continue operation for an additional
20 minutes.
Operating instructions
The spa control system has automatic functions that operate upon
start-up and normal operation to protect the system.
Upon power up, the display shows the following information:
I
current software version;
I
"888" (all LED indicators are on: control of operation of all dis-
play segments and indicator lights).
I
After the initial start-up sequence ends, the actual water tem-
perature is displayed. If water temperature is below 38° C (facto-
ry setting) and the spa is set in skimming/heating mode, the
24
) Button: Increases water temperature set point.
) Button: Turns jets pump #1 on and off. Press
) Button (J-335/J-345/J-355/J-365/J-375/J-
) Button: Allows access to the programming