Enabling of management for opening with automatic re-closure exclusion
If enabled, the exclusion of automatic re-closure only applies for the command selected via the parameter. For example:
if you set
, automatic re-closure is excluded following an AP command, but it is activated following a PP or PED
command.
NOTE: The command has open-stop-close or close-stop-open sequence activation function.
Disabled.
An AP (open) command activates the opening manoeuvre. With the gate fully open, automatic reclosing is excluded.
Another AP (open) command activates the closure manoeuvre.
A PP (step mode) command activates the opening manoeuvre. With the gate fully open, automatic reclosing is exclu-
ded. Another PP (step mode) command activates the closure manoeuvre.
A PED (partial opening) command activates the partial opening manoeuvre. Automatic re-closure is excluded. Another
PED (partial opening) command activates the closure manoeuvre.
Setting reverse time after activation of sensing edge or obstacle detection
(crush prevention)
This sets the reverse manoeuvre time after activation of the sensing edge or the obstacle detection system. The gate co-
mes to a stop after reversal dues to activation of the sensing edge or obstacle detection system at the end of manoeuvre
deceleration speed. As a result, the effective reversal manoeuvre time is slightly longer than the set time.
From 0 to 60 s.
Setting motor torque
Increasing or decreasing the value of the parameter increases or decreases motor torque and, as a result, adjusts
obstacle detection sensitivity.
Use values below
ONLY for particularly lightweight installations not exposed to severe weather conditions (strong
winds or very cold temperatures).
01= -35%; 02= -25%; 03= -16%; 04= -8% (reduced motor torque = increased sensitivity).
05= default motor torque setting.
06= +8%; 07= +16%; 08= +25%; 09= +35% (increased motor torque = reduced sensitivity).
Setting obstacle impact force sensitivity
If the reaction time to obstacle impact force is too long, reduce the value of the parameter. If the impact force exerted
on obstacles is too high, reduce the value of parameter 30.
Low motor torque:
01 = minimum obstacle impact force ... 10 = maximum obstacle impact force
N.B.: only use these settings if the medium motor torque values are not suitable for the installation.
Medium motor torque. Recommended setting for adjusting force settings correctly.
11 = minimum obstacle impact force ... 16 = maximum obstacle impact force.
70% of maximum motor torque, 1 s of reaction time. Sensing edge is compulsory.
80% of maximum motor torque, 2 s of reaction time. Sensing edge is compulsory.
Maximum motor torque, 3 s of reaction time. Sensing edge is compulsory.
Maximum motor torque, 5 s of reaction time. Sensing edge is compulsory.
Setting start acceleration during opening and closing
See chapter 14-15 "Special parameters for High Speed and Reversible series"
01= the gate accelerates rapidly at start of manoeuvre ... 05= the gate accelerates slowly and progressively at start of
manoeuvre.
Enabling maximum torque boost at start of manoeuvre
If this parameter is enabled, each time the motor starts a manoeuvre, maximum torque is produced for a maximum of
5 seconds, or for the time necessary for the gate to open by approximately 65 cm.
N.B: in the case of High Speed motors, a motor boost mode is implemented for 2 seconds after each gate start, re-
gardless of the setting of parameter
Disabled.
Enabled at start of opening manoeuvre only (including position recovery). The motor starting current function is only
enabled for closing manoeuvres if the gate position is known and the gate is at least 2 metres from the completely
closed position.
Enabled for all starts (including position recovery).
.