Commands and Accessories
If not installed, safety devices with NC contacts must be jumpered at the COM terminals,
or disabled by modifying the parameters
KEY:
N.A. (Normally Open) .
N.C. (Normally Closed).
CONTACT
6
7(COR) Output (potential free contact) for connecting courtesy light. 230 Vac 100 W - 24 Vac/dc 40
6
7(COR) Error alert contact only, for:
8(+SC)
9(COM) Connection for gate open indicator lamp. 24 Vdc 3 W.
8(+SC)
9(COM) Photocell test connection
10(FT2)
28(COM) Input (NC) for connecting photocells FT2
11(FT1)
28(COM) Input (NC) for connecting photocells FT1
12(COS2)
14(COM) Input (NC or 8 kOhm) for connecting sensing edge COS2
13(COS1)
14(COM) Input (NC or 8 kOhm) for connecting sensing edge COS1
15(ST)
14(COM) STOP command input (NC).
DESCRIPTION
NOTE: Provide a protective fuse.
• Unlocked gate / battery supply error (low battery);
The COR output operating mode is managed by parameter
The voltage level of the battery can be set via parameter
The function of the indicator lamp is determined by parameter
Set the parameter
to enable the test function.
Each time a command is received, the control unit switches the photocells off and on to
check that the contact changes state correctly.
Power feeds for all external devices may be connected to reduce battery consumption (if
batteries are used). Set
WARNING! If contact 8-SC is used for the photocell test function or battery saving function,
a gate open indicator lamp cannot be connected.
The photocells FT2
. Photocell FT2 disabled when gate is opening.
. Photocell FT2 disabled when gate is closing.
. The gate opens when an open command is received if photocell FT2 is obstructed.
If the photocells are not installed, jumper the terminals 28(COM) - 10(FT2) or set the
parameters
and
WARNING! Use F4ES or F4S series photocells.
The photocells FT1
. Photocell triggers only during gate closure. Photocell is ignored during gate
opening.
. Movement is reversed if the photocell is triggered during gate closure.
. The gate opens when an open command is received if photocell FT1 is obstructed.
If the photocells are not installed, jumper the terminals 28(COM) - 11(FT1) or set the
parameters
and
WARNING! Use F4ES or F4S series photocells.
. The sensing edge COS2 (NC contact) is disabled.
If the sensing edge is not installed, jumper the terminals 12(COS2) - 14(COM) or set the
parameter
.
. The sensing edge COS1 (NC contact) is disabled.
If the sensing edge is not installed, jumper the terminals 13(COS1) - 14(COM) or set the
parameter
.
The current manoeuvre is arrested if the safety contact opens.
N.B.: the controller is supplied with this contact already jumpered by ROGER TECHNOLOGY.
,
,
,
,
or
.
.
.
and
.
.
.
.
.
.
65