B: Advanced Wiring

Wiring Configuration: Advanced Models (HE150/HE250/HE300)
Wiring HumidiPRO to TrueEASE Advanced Humidifier with Fan Interlock.
Wiring to force the HVAC system fan on whenever humidity is needed (on demand).
Humidifier 69-2413EF—19
G OR W
OR
2
C
HumidiPRO
C
R
U
U
S
OUTDOOR
S
SENSOR
1
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.
HE300 USES A LINE CORD PLUG.
2
CONNECT G TO HUMIDIFY WHEN THERE IS A FAN CALL.
CONNECT W TO HUMIDIFY WHEN THERE IS A HEAT CALL.
NEVER CONNECT BOTH. CONNECT C WHEN USING G OR W.
3
USE AIR PROVING DEVICE INSTEAD OF THE G/W CONNECTION
TO HUMIDIFY ANY TIME THE FAN IS OPERATING.
G (THERMOSTAT)
1
HumidiPRO
C
R
R
U
U
G (FURNACE)
S
OUTDOOR
S
SENSOR
1
ONLY NEEDED IF SYSTEM'S THERMOSTAT DOES NOT ISOLATE Y FROM G.
IF NEEDED, BREAK THE THERMOSTAT G TO SYSTEM G CONNECTION
AND ROUTE THROUGH HUMIDIFIER AS SHOWN.
2
HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN.
HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN.
HE300 USES A LINE CORD PLUG.
AIR PROVING
3
DEVICE
1
POWER IN
LEFT
LEFT
M35152
2
POWER IN
RIGHT
RIGHT
M35154
27