Any permanent electrical installation must comply with the lastet I.E.E Regulations and local
G B
G B
Electricity Board regulations. For your own safety this should be undertaken by a qualified elec-
trician e.g. your local Electricity Board, or a contactor who is on the roll of the National Inspection
Council for Electrical Installation Contracting (NICEIC).
Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage
FUSE
FUSE
FUSE
ON
ON
ON
on the rating inside the cooker hood.
This appliance is fitted with a 2 core mains cable and must be permanently connected to the
electricity supply via a double-pole switch having 3mm minimum contact gap on each pole.
BLUE (NEUTRAL)
BROWN (LIVE)
A switched Fuse Connection Unit to BS.1363 Part 4, fitted with a 3 Amp fuse, is a recommended
mains supply connection accessory to ensure compliance with the Safety Requirements appli-
cable to fixed wiring instructions.
L
The wires in this mains lead are coloured in accordance with the following code :
L supply
N
Green & yellow :
DP
Blue :
N Supply
Brown :
As the colours of the wires in the mains lead of this appliance may not correspond with the co-
loured markings identifying the terminals in your connection unit, proceed as follows :
GREEN & YELLOW
(EARTH)
The wire which is coloured blue must be connected to the terminal which is marked with the
letter 'N' or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked with the
letter 'L' or coloured red.
C H
C H
N
24.5
7
25.5
7
L
COMPOSANTS/COMPONENTS
Neutral
E
23
4
15.8
E
35.5
Earth
Live
Fiche de sécurité class 1, 250V~ 10A - 2 poles + terre
Spira di sicurezza classe 1, 250V~ 10A - 2 poli + terra
Stecker der Schutzklasse 1, 250V~ 10A
Zweipolig mit Schutzkontakt (Erde)
SEV 1011, SN416534-2, CH-Typ 12
N
19
19
6 min
8.5 min
L