Positioning, installation and commissioning
must be carried out by trained contractors,
in accordance with these operating and
installation instructions.
The manufacturer's warranty only applies,
if the WWK 300 is installed, connected and
operated in accordance with these operating
and installation instructions.
In conjunction with the positioning/
installation, observe all local/national
standards and requirements, as well as the
stipulations by your local water board and
energy supply company.
Risk of injury
Where children or persons with lim-
ited physical, sensory or mental capabilities
are to be allowed to control this appliance,
ensure that this will only happen under
supervision or after appropriate instructions
by a person responsible for their safety.
Children should be supervised to ensure
that they do not play with the appliance.
12
12
Heat output
Average heating output (EN 16147 / A15)
Power consumption
Average heat pump power consumption (EN 16147 / A15)
13
Power consumption, emergency/booster heater
Max. power consumption heat pump + emergency/booster heater
13
13
COPs to EN 255
13
Coefficient of performance at A15/W15-55 (EN 255) 
13
Output details to EN 16147
Selected set DHW temperature
Nominal draw-off profile (EN16147)
13
Draw-off hot water temperature (EN 16147 / A15)
13
Maximum available amount of DHW at 40 °C (EN 16147 / A15)
14
Heat-up time (EN 16147 / A15)
14
Power consumption, standby period (EN 16147 / A15)
COP (EN 16147 / A15)
Sound data
15
Sound pressure level at 1 m distance in a free field
15
Sound power level (EN 12102)
15
Application limits
16
Maximum DHW temperature with heat pump
16
Maximum DHW temperature with emergency/booster heater (top third)
16
Max. permissible heat transfer temperature
16
Permissible maximum DHW temperature inside the cylinder
17
Heat source min./max. application limits
18
Min. installation room floor area
19
Min. installation room volume
19
Permissible operating pressure, cylinder
Hydraulic data
Rated capacity
Surface, indirect coil
Electrical details
Phases
Frequency
Rated voltage
Fuses
Versions
IP-Rating
Refrigerant
Refrigerant capacity
Dimensions
Height
Width
Depth
Height of unit when tilted
Height when tilted incl. packaging
Weights
Weight (wet)
Weight (dry)
Connections
Condensate drain
DHW circulation connection
Water connection
Heat exchanger connection
Values
Air flow rate
The specifications apply to appliances without an air duct connection. As long as the air
!
flow rate is not reduced by more than 10 %, the heat-up time will not increase. In the
case of an air supply via an air duct, the required air flow rate is assured if the connected air
duct, with a diameter of 200 mm, is not longer than 4 m.
Only connect the air duct to the air inlet side of the appliance. Prevent additional pressure drops
caused by diverters or the installation of grilles and filters.
WWK 300 WWK 300 SOL
074361
074362
kW
1,65
1,65
kW
0,49
0,49
kW
1,50
1,50
kW
1,99
1,94
4,10
4,10
°C
55
55
L
°C
52,7
52,7
l
379
303
h
9,68
9,68
kW
0,040
0,040
3,34
3,34
dB(A)
45
45
dB(A)
60
60
°C
55
55
°C
65
65
°C
75
°C
65
65
°C
6-35
6-35
m2
6
13
13
MPa
0,6
0,6
l
303
284
m2
1,3
1/N/PE
1/N/PE
Hz
50
50
V
230
230
C 16
C 16
IP21
IP21
R134a
R134a
kg
0,850
0,850
mm
1792
1792
mm
660
660
mm
690
690
mm
1920
1920
mm
2050
2060
kg
460
464
kg
157
180
G 3/4
G 3/4
G 1/2
G 1/2
22 mm
22 mm
G 1
m³/h
550
550
L
6